April 9, 2014 7044-225B 3
31-I ACC
Model: 3100-I(ACC)Insert
Laboratory: OMNITestLaboratories,Inc.
Report No: 061-S-74-6.2
Type: SolidFuelType,ListedRoomHeater
Standard: UL1482 and ULC S628-93 and
(UM)84-HUD,MobileHome
Approved.
EPACertied: 2.0 grams per hour
Efciency: up to 79.8%
EPA BTU Output: 11,800 to 32,000
Heating Capacity: upto1800sqftdepending
on climate zone
Vent Size: 6 inches
Firebox Size: 1.9cubicfeet
Max Wood Length: 18 inches
Max First Hour BTUs: 57,100 @ 75.3% B415
TestedEfcienty
Fuel: Cord Wood
Shipping Weight: 345lbs
TheQuadra-Fire3100WoodInsert(ACC)meetstheU.S.Environ-
mentalProtectionAgency’s1990particulateemissionstandards.
1 Important Safety Information
A.InsertCertication
NOTE:Hearth&HomeTechnologies,manufacturerof
thisappliance,reservestherighttoalteritsproducts,their
specicationsand/orpricewithoutnotice.
NOTE:Thisinstallationmustconformwithlocalcodes.Inthe
absenceoflocalcodesyoumustcomplywiththeUL1482,(UM)
84-HUDandNPFA211intheU.S.A.andtheULCS628-93and
CAN/CSA-B365InstallationCodesinCanada.
C. Mobile Home Approved
• Thisapplianceisapprovedformobilehomeinstalla-
tions when not installed in a sleeping room and when
anoutsidecombustionairinletisprovided.
• Thestructuralintegrityofthemobilehomeoor,ceil-
ing,andwallsmustbemaintained.
• Theappliancemustbeproperlygroundedtotheframe
ofthemobilehomewith#8coppergroundwire,and
chimneymustbelistedtoUL103 HToralistedUL-
1777fulllengthsixinch(152mm)diameterlinermust
beused.
• OutsideAirKit,partOAK-ACCmustbeinstalledina
mobilehomeinstallation.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
Forassistanceoradditionalinformation,consultaqualied
installer,serviceagencyoryourdealer.
Quadra-FireisaregisteredtrademarkofHearth&Home
Technologies.
• Installationanduseofanydamagedappliance.
• Modicationoftheappliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installationand/oruseofanycomponentpartnotapprovedby
Hearth&HomeTechnologies.
• Operatingappliancewithoutfullyassemblingallcomponents.
• Operatingappliancewithoutlegsattached(ifsuppliedwithunit).
• DoNOTOverre-Ifapplianceorchimneyconnectorglows,you
areoverring.
Anysuchactionthatmaycausearehazard.
WARNING
Fire Risk.
Hearth&HomeTechnologiesdisclaimsany
responsibilityfor,andthewarrantywillbevoided
by,thefollowingactions:
B.BTU&EfciencySpecications
D.GlassSpecications
Thisstoveisequippedwith5mmceramicglass.Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
Hearth&HomeTechnologiesWILLNOTwarrantystoves
thatexhibitevidenceofover-ring.Evidenceofover-ring
includes,butisnotlimitedto:
• Warpedairtube
• Deterioratedrefractorybrickretainers
• Deterioratedbafeandotherinteriorcomponents
E. Non-Combustible Materials
Materialwhichwillnotigniteandburn,composedofany
combinationofthefollowing:
- Steel - Plaster
- Brick - Iron
-Concrete -Tile
- Glass - Slate
Materials reported as passing ASTM E 136, Standard
Test Method for Behavior of Metals, in a Vertical Tube
Furnace of 750° C.
F. Combustible Materials
Materialmadeof/orsurfacedwithanyofthefollowingma-
terials:
- Wood - Compressed Paper
-PlantFibers -Plastic
-Plywood/OSB -SheetRock(drywall)
Anymaterialthatcanigniteandburn:ameproofedornot,
plastered or un-plastered.