REED R8085 Bedienungsanleitung

Noise
Dosimeter
Instruction
Manual
R8085
www. .com information@itm.com1.800.561.8187

2
Table of Contents
Introduction ................................................................................................ 3
Product Quality........................................................................................... 4
Safety ......................................................................................................... 4
Features...................................................................................................... 4
Specications..........................................................................................5-7
Comparison of Frequency Weightings and Tolerance Limits................. 7
Time Weightings (Fast & Slow) Characteristics...................................... 7
Included...................................................................................................... 7
Instrument Description............................................................................... 8
Display Description .................................................................................... 9
%DOSE.................................................................................................. 9
Sound Pressure Level (SPL)................................................................... 9
Operating Instructions.........................................................................10-11
Power On/Off ....................................................................................... 10
Sound Pressure Level (dBA/dBC Mode).............................................. 10
Data Hold ............................................................................................. 11
Recording Maximum and Minimum Readings..................................... 11
Backlighting ......................................................................................... 11
What is Dose Noise Exposure?...........................................................11-15
Noise Exposure (%DOSE) - Test Duration Mode ............................12-13
Noise Exposure (%DOSE) - Programmable Time Mode.................13-15
%DOSE Testing Notes: ........................................................................ 15
Data Logging.......................................................................................15-16
Sound Pressure Level (SPL) Data Recording Modes........................... 15
SPL Manual Data Logging Mode ...............................................15-16
SPL Automatic Data Logging Mode ............................................... 16
Setup Mode.........................................................................................16-21
Setting the Time and Date (dAtE)......................................................... 17
Setting the Data Logging Sampling Rate (SP-t)................................... 17
continued...
www. .com information@itm.com1.800.561.8187

3
Enabling/Disabling Auto Power OFF (PoFF) ...................................17-18
Setting the Criterion Level in dB (SEt LC)............................................ 18
Setting the Threshold in dB (SEt LT) .................................................... 18
Setting the Exchange Rate in dB (SEt ER)........................................... 18
Checking Memory Space (SPC) .......................................................... 19
Clearing Stored Data (CLrE)................................................................. 19
Verify Set Time, Date and Sampling Rate ............................................ 19
Calibration Procedure .....................................................................19-20
Data Stream Output ............................................................................. 20
3.5mm Terminal to RS-232 Serial Connection..................................... 21
Battery Replacement................................................................................ 21
Applications.............................................................................................. 21
Accessories and Replacement Parts ....................................................... 22
Appendix A: USA Regulations - OSHA Regulation
Conversion Charts.................................................................................... 22
Appendix B: Canada Regulations - Occupational Health and Safety
Regulations, Occupational Exposure Limits ............................................ 23
Appendix C: Noise Exposure Limits, by
Canadian Jurisdiction............................................................................... 24
Appendix D: Regulations Conversion from "Percent Noise Exposure"
or "DOSE" to "8-Hour Time-Weighted Average Sound Level" (TWA)...... 25
Product Care ............................................................................................ 25
Product Warranty ..................................................................................... 26
Product Disposal and Recycling .............................................................. 26
Product Support....................................................................................... 26
Introduction
Thank you for purchasing your REED R8085 Noise Dosimeter. Please
read the following instructions carefully before using your instrument. By
following the steps outlined in this manual your meter will provide years of
reliable service.
www. .com information@itm.com1.800.561.8187

4
Product Quality
This product has been manufactured in an ISO9001 facility and has been
calibrated during the manufacturing process to meet stated product
specications. If a certicate of calibration is required please contact the
nearest authorized REED distributor or authorized Service Center. Please
note an additional fee for this service will apply.
Safety
Never attempt to repair or modify your instrument. Dismantling your
product, other than for the purpose of replacing batteries, may cause
damage that will not be covered under the manufacturer's warranty.
Servicing should only be provided by an authorized service center.
Features
• Noise Dosimeter, Sound Level Meter and Data Logger
• High accuracy of ±1.0dB meets Type 2 standards
• Designed to meet noise survey requirements in compliance with OSHA
and CCOHS regulations
• Personal sound exposure meets IEC 61252, ANSI S1.25
• A & C frequency weighting
• Fast & Slow time weighting
• Lightweight and compact design
• Adjustable Criterion Level, Exchange Rate and Threshold
• USB interface with Windows®compatible software to retrieve stored
data (sold separately)
• Easy-to-read backlit LCD display
• Data hold and Min/Max hold
• Tripod mount for long-term monitoring
• Low battery indicator and auto shut off
www. .com information@itm.com1.800.561.8187

5
Specifications
Measurement Type: Sound Pressure Level: dB
Personal Noise Exposure: %Dose
Measuring Range(s): 35 to 130dB
Low: 35 to 80dB
High: 80 to 130dB
Auto: 35 to 130dB
Dose: 70 to 130dB
Dynamic Range: 50dB (in each range)
Accuracy:
31.5Hz ±3.0dB, 63Hz ±2.0dB, 125Hz ±1.5dB,
250Hz ±1.5dB, 500Hz ±1.5dB, 1kHz ±1.0dB,
2kHz ±2.0dB, 4kHz ±3.0dB, 8kHz ±5.0dB
Resolution: 0.1dB
Response Time: Approx. 1 second
Frequency Range: 31.5Hz to 8kHz
Frequency Weighting: A, C
Time Weighting: Fast/Slow (125mS and 1 second)
Microphone: 0.5" (12.7mm) electret condenser
Display: 4-digit LCD
Backlit Display: Yes
Data Hold: Yes
Min: Yes
Max: Yes
Alarm Indicators: Over (visual on-screen)
Datalogging Capabilities: Yes
Real-Time Clock and
Date Stamp: Yes
Selectable Sampling Rate: Yes (1, 2, 5, 10, 30, 60, 120, 300,
600, 1800, 3600 seconds)
continued...
www. .com information@itm.com1.800.561.8187

6
Selectable Dose
Measurement Rate: Yes (0, 1, 5, 10, 15, 30 minutes/
1, 2, 4, 8, 10, 12, 24 hours)
Auto Shut-off: Yes (after 10 minutes/off)
Tripod Mountable: Yes
Low Battery Indicator: Yes
Power Supply: 3 x AAA batteries
Output: Yes, RS-232/USB (optional)
PC Connectivity: USB Cable (R8085-USB, optional)
Software: PC Software (R8085-PC, optional)
Software OS Compatability: Windows XP/Vista/7/8/10
Product Certications: CE, IEC61252, ANSI S1.25 for Noise Dose
and Sound Exposure Meters,
IEC 61672 Class 2/ANSI S1.4 Type S
for Sound Level Meters
Operating Temperature: 32 to 122°F (0 to 50°C)
Storage Temperature: 14 to 140°F (-10 to 60°C)
Operating Humidity Range: <85%
Dimensions: 4.2 x 2.3 x 1.0" (107 x 58 x 25mm)
Weight: 4.3oz (122g)
continued...
www. .com information@itm.com1.800.561.8187

7
Comparison of Frequency Weightings and Tolerance Limits
Frequency
Hz
A Weighting
Characteristics
C Weighting
Characteristics
Tolerance
(IEC 61672
class 2)
31.5 -39.4dB -3dB
±3.0
dB
63 -26.2dB -0.8dB
±2.0
dB
125 -16.1dB -0.2dB
±1.5
dB
250 -8.6dB 0dB
±1.5
dB
500 -3.2dB 0dB
±1.5
dB
1K 0dB 0dB
±1.0
dB
2K +1.2dB -0.2dB
±2.0
dB
4K +1dB -0.8dB
±3.0
dB
8K -1.1dB -3dB
±5.0
dB
Time Weightings (Fast & Slow) Characteristics
Time Weighting
Characteristics
Max Response
Reference
continuous Signal
Tolerance
(IEC 61672 class 2)
F (Fast) -1.0dB
±1.0
dB
S (Slow) -4.1dB
±1.0
dB
Included
• Dosimeter
• Microphone with Clip
• Batteries
• Wrist Strap
• Carrying Case
www. .com information@itm.com1.800.561.8187

8
Instrument Description
3
4
5
14
13
12
9
6
7
8
10
15
16
R8085
Noise Dosimeter
11
ESC
HOLD RUN/
PAUSE
DUR/BEG TIME
SET LOG
ENTER
FUNC.
UNLOCK
1. LCD Display
2. HOLD Button
3. Power/ESC/Backlight Button
4. Up/Duration/Begin/Fast/
Slow/dB Range Button
5. FUNCTION/SET Button
6. Microphone Input Jack
7. RUN/PAUSE Button
8.
Down/A/C/TIME Check Button
9. ENTER/LOG Button
10. Wrist Strap Anchoring Point
11. RS-232 Output Jack
12. Tripod Mounting Screw
13. Battery Cover
14. Battery Cover Screw
15. Microphone
16. Microphone Plug
www. .com information@itm.com1.800.561.8187

9
Display Description
%DOSE
1. Test Duration, Start
(BEG), Stop (END)
Indicators
2. Locked Keypad
Indicator
3. Test Duration
Time Value
4. Time Stamp
5. Time Weighting
Indicator
6. Unit of Measure
7. Frequency Weighting Indicator
8. Recording Status Indicator
9. %DOSE Measurement
Sound Pressure Level (SPL)
1. dB Range Indicator
2. Time Weighting
Indicator
3. Unit of Measure
4. Frequency Weighting
Indicator
5. Sound Level
Measurement
6. Max/Min Recording
Indicator
3
4
9
5
6
7
8
BEG
END
DUR
FAST
%DOSE
m.s.
A
3
4
5
FAST
A
dB
6
REC
www. .com information@itm.com1.800.561.8187

10
Operating Instructions
Power On/Off
Turn the meter on by pressing the POWER button. To turn the meter off,
press and hold the POWER button for 2 seconds.
Sound Pressure Level (dBA/dBC Mode)
1. At start up, the meter's default settings are "Auto Range",
"A Frequency Weighting" and "Fast Time Weighting".
2. Press and hold the button to select the desired Response Time. If
the sound source consists of short bursts, set the response to FAST
(125ms). To measure average sound level, select SLOW (1 second).
3. Press and hold the button to select the Frequency weighting.
Select "A" Weighting for a general noise sound level, or "C"
Weighting for measuring high level noise. "C" Weighting is a
standard weighting of the audible frequencies commonly used for
the measurement of Peak Sound Pressure Level. If the "C" Weighted
level is much higher than the "A" Weighted level, then there will be a
large amount of low-frequency noise.
4. Press the button to scroll through the three dB range types. There
are two manual dB ranges to select from and an auto range. The
manual ranges are described as follows:
Low (as indicated by "L"): 30 to 80dB range
High (as indicated by "H"): 80 to 130dB range
5. The meter can be held comfortably in one hand, placed in a pocket
or positioned on a tripod for long-term monitoring.
6. Attach the microphone with the provided clip to an area where it will
be exposed to sound levels (i.e. shirt collar).
Note: Set the cable in a way that does not hinder the working movements
of the user. Direct contact with strong winds or blowing air on the
microphone may cause measurement errors.
continued...
www. .com information@itm.com1.800.561.8187
Inhaltsverzeichnis
Andere REED Messgerät Handbücher

REED
REED ST-9809 Bedienungsanleitung

REED
REED R8150 Bedienungsanleitung

REED
REED R5010 Bedienungsanleitung

REED
REED SD-230 Bedienungsanleitung

REED
REED R5015 Bedienungsanleitung

REED
REED R8060 Bedienungsanleitung

REED
REED R5007 Bedienungsanleitung

REED
REED R3001 Bedienungsanleitung

REED
REED SD-947 Bedienungsanleitung

REED
REED SD-4214 Leitfaden

REED
REED R7150 Bedienungsanleitung

REED
REED R5800 Bedienungsanleitung

REED
REED R2800 Bedienungsanleitung

REED
REED DW-6060 Bedienungsanleitung

REED
REED R5050 Bedienungsanleitung

REED
REED ST-3347 Bedienungsanleitung

REED
REED R8080 Bedienungsanleitung

REED
REED 5A Bedienungsanleitung

REED
REED R3002 Bedienungsanleitung

REED
REED R5060 Bedienungsanleitung