ROOTS RS-V5000 Bedienungsanleitung

1TMV RS-V5000
Read this manual completely and understand the
instructions before operating the machine.
“English Version”
RS - V5000
Truck Mounted Vacuum
Diesel
Operator’s Manual

2TMV RS-V5000

3TMV RS-V5000
P/N: 557480030-00, Rev-A, 04/2018
Prepared by KM, NPM TD Dept.
TABLE OF CONTENTS
IMPORTANT NOTE:
Roots Multiclean Ltd. (RMCL) is not liable for any legal claims that
may arise as a direct or indirect result of the contents of this
manual.
Roots Multiclean Ltd.
R.K.G. Industrial Estate, Ganapathy,
Coimbatore - 641 006, India.
MACHINE DATA
Please fill at the time of installation for future reference:
Model No. - _______________________________
Serial No. - ________________________________
Engine No. - _______________________________
Blower No. - _______________________________
Accessories - ______________________________
Installation Date - ___________________________
Introducon
Support
Know Your Machine
Main Components of the Machine
Engine - Fuel Tank
Troubleshoong
Machine Operaon
Operator Notes
Table Of Contents & Important Note
Technical Specificaons
Safety Instrucons
Working Principle
Controls
Maintenance
Hopper
Do & Don’ts
5
10
24
31
40
81
46
86
3
7
12
29
34
56
43
85

4TMV RS-V5000 INTRODUCTION

5TMV RS-V5000
PREFACE
We are pleased with you having chosen the RS-V5000 Truck Mounted
Vacuum for your cleaning requirements. Backed by our industry expertise
that spans across two decades, we assure you that the machine comes with
ROOTS promise of quality, efficiency and performance.
We advise you to carefully read through the instructions prior to the
operation of the machine. This manual contains detailed instructions for the
proper operation of the machine, along with important information
regarding its handling, care, maintenance and service needs.
We are sure that you will find the machine and its performance to your
utmost satisfaction. Once again, we thank you for choosing as a trusted us
partner for your cleaning requirements.
Usage, Handling & Modification
Use of the product beyond the specified scope of functioning is deemed
improper and the manufacturer cannot be held liable for any damages which
may arise due to this.
This machine may be used only by persons who are trained or are familiar
with the machine and are aware of the possible hazards involved. The
appropriate Accident Prevention Regulations as well as applicable general
regulations pertaining to Safety and Health at the work place must be
adhered to by the user.
Modifications made to machine without the manufacturer's consent will
relieve the manufacturer of responsibility and any possible liability for
consequential damage.
Dear Customer,
Acceptance of the Machine
On arrival of the machine at the shipping address, please check for any
damage that may have occurred as a result of transit. In the event of any such
damage, the purchaser is bound by responsibility to send a claim letter to the
concerned dealer with a copy of the invoice. The letter should be authorized
sent within 24 hours of receipt of the machine.
Notes on Warranty
Refer the Warranty manual supplied along with the machine.
NOTE:
ILLUSTRATIONS SHOWN IN THIS MANUAL ARE FOR REPRESENTATIVE
PURPOSE ONLY. ACTUAL PRODUCT MAY VARY.
ROOTS reserves the right to change the product or contents of this manual
without prior information.
For Engine, Battery, Motors, Blowers or other OEM components related
information kindly refer to their manufacturers manual supplied along
with the machine for instructions regarding usage, maintenance and
service.
INTRODUCTION
Prior to first operation, read the manual carefully and strictly comply with
the instructions contained.
The Operator’s Manual is an integral part of the machine and must not be
misplaced.

6TMV RS-V5000 TECHNICAL SPECIFICATION

7TMV RS-V5000
TECHNICAL SPECIFICATION
Empty weight - 4500 kg
Type of fuel - Diesel
Tank capacity - 150 liters
Manufacturer
Type
Construcon
Bearings
Sha
Drive
Air flow (max.)
Vacuum pressure
(max.)
Pressure relief valve
Max. pump temp
Robuschi
3 lobe rotary with
atm air injecon
Cast iron
2 sealed bearings
60 mm diameter
5 XPB secon banded
individual V belt
3000 m³/h (1765CFM)
700 mbar (21” of HG)
610 mbar (18” of HG)
140 °C
-
-
-
-
-
-
-
-
-
-
Hopper
Steel
Construcon
Volumetric capacity
Useable capacity
Dumping method
Dump door
Dump height
Heavy gauge carbon steel
5 mm (6 gauge) for walls & floor
Welded carbon steel
8 m³ (10.4 cubic yards)
5 m³
Rear door dump
1350 mm self locking
hydraulic fingers
1100 mm
-
-
-
-
-
-
-
-
Manufacturer
Model
Displacement
Horsepower
Net torque
Air cleaner
Oil filter
Radiator fan
Electrical
Ashok Leyland
4 cylinder diesel,
water cooled
3839 cc
101 Hp/75kW
@2200 rpm
390 Nm@1440-1600 rpm
Spin on type
Spin on type
Pusher
24V
-
-
-
-
-
-
-
-
-
ENGINE
VACUUM
HOPPER
Drive
Pump type
Reservoir
Filtraon
Funcon
PTO gear pump from
aux. engine
Fixed displacement
34 Liters
10 micron spin-on
inline mounted
Hopper lng & rear door
lock open and close
-
-
-
-
-
HYDRAULIC
FUEL

8TMV RS-V5000
TECHNICAL SPECIFICATION
Type
Cleaning method
Blast orifice
Funcon
Filtraon area
Bag filter -
Filtraon size
Bag filter material
Pump cooling filter
Secondary filter
No. of secondary filters
Purging tank capacity
Air tank capacity
Air compressor
Bag type - Primary
Reversible pulse jet
High pressure located in top
Separate blast orifice
for each bag
34 sq.m
3 microns
Felt polyester 550 g/sq.m
Cartridge type, 1 micron
Cartridge type, 1 micron
3
11 Liters
60 Liters
230 cc, engine direct driven
-
-
-
-
-
-
-
-
-
-
-
-
-
Shutdown system 3 point system
(LLOP, HWT,Over speed)
Emergency Stop Switch
-
Width - 2100 mm
Length - 5411 mm
Height - 2200 mm
Standard:
Fluidized bulk nozzle
Bulk nozzle
100 dia hose x 20 meters
Hose connectors
Oponal:
Extension hose
Special filters
FILTER
Display size
Warnings
Electrical
control panel
Ignion switch
Filtraon switch
5 inch
Indicaon & buzzer
Body mounted
Start/Stop-push buon
Auto/Manual (adj. me)
-
-
-
-
-
DISPLAY
SAFETY SYSTEM
ACCESSORIES
Baery - 24V, 80Ah
BATTERY

9TMV RS-V5000 SUPPORT

10TMV RS-V5000
AFTER SALES SUPPORT
CUSTOMER SUPPORT SYSTEM (CSS) ANNUAL MAINTENANCE CONTRACT (AMC)
RMCL has a dedicated CSS Team to ensure prompt after sales service
support. One call solution for all your complaints/concerns. Register your
complaint or concern through the below toll free number for hassle free
support. The customer support executive registers your complaint/concern
and will keep you updated on the progress.
Toll Free Number:
1800 41 99 77 9
Our timings (Monday to Saturday):
8:00 am to 7:00 pm
Customer Support System Process
Customer CSS Executive Engineer Site Location
AMC or Annual Maintenance Contract is a professional and
timely maintenance cover offered by RMCL to its customers.
AMC takes care of scheduled and preventive maintenance services.
Equipment under AMC qualifies for four scheduled visits and to a maximum
of twelve unscheduled visits during the contract.
Advantages of AMC:
þPan India network presence.
þMaximum equipment uptime.
þFocus on your business while we take care of your equipment.
þWell trained engineers to take care of the equipment.
þSystem driven scheduled periodic maintenance.
þGenuine spare parts.
þToll free number assistance for breakdown.
AMC
Our Address:
Roots Multiclean Ltd.
R.K.G. Industrial Estate, Ganapathy, Coimbatore - 641 006, India.
Phone: +91 (422) 4330 330, E-mail: [email protected]om
Web: rootsmulticlean.in
Toll Free: 1800 41 99 77 9
Inhaltsverzeichnis
Andere ROOTS Staubsauger Handbücher
Beliebte Staubsauger Handbücher anderer Marken

Bissell
Bissell LittleGreen Proheat 1425 Series Bedienungsanleitung

Panasonic
Panasonic MC-YL637S147-AE Bedienungsanleitung

NEFF
NEFF N17XH10 0 Series Bedienungsanleitung

LG
LG A9 Series Bedienungsanleitung

Oreck
Oreck Cordless Captura BK51700 Series Bedienungsanleitung

Kogan
Kogan KAVACROBVWA Bedienungsanleitung