SHEKEL MERAV-6000 Bedienungsanleitung

HL318LC Weighing Indicator
User Manual
SH.01

1
Warning
Ask professional personnel to debug, detect and repair
controller.
Warning
Please keep good grounding of controller.
Warning
In electrical connection of controller, please cut off the power
supply in advance. Wait for 30 seconds between power-on of the
controller for 2 times.
Pay Attention to Static Electricity

2
Contents
!"
TECHNICAL INDICATORS ..................................................................................................... 3
#"
MAIN FUNCTION ............................................................................................................... 3
$"
BOUNDARY DIMENSION .................................................................................................... 4
%"
INTRODUCTION TO PANEL ................................................................................................. 5
&"
SETTING OF PARAMETERS .................................................................................................. 7
ENTRY SETTING .........................................................................................................
F1 SETTING OF SCALE ............................................................................................................................. 7
F2 SETTING OF APPLICATION FUNCTION ..................................................................................................... 9
F3 SETTING OF ENERGY SAVING PARAMETERS ........................................................................................... 10
F4 SETTING OF SERIAL PORT .................................................................................................................. 11
F5 MAINTENANCE AND SERVICE ............................................................................................................. 11
'"
FUNCTION DESCRIPTION .................................................................................................. 12
APPENDIX 1. CONTINUOUS OUTPUT FORMAT SPECIFICATION ............................................. 1616
APPENDIX 2. PRINTING FORMAT SPECIFICATION ..................................................................... 16

3
1
、
Technical Indicators
● 6-digit 1.6-inch LCD display. Long service life and shock resistance
● 7 function keys. Operation is simple and convenient
● Protection level: IP5X
● Excitation voltage: +5VDC
● Load capacity of sensor: at most 4 350Ω simulation sensors
● Input signal range of null point: 0-5mV
● Input signal range of full scale: 1-10 mV
● Inner resolution: 1 million
● Weight upgrading rate: 40 times per second
● Power supply mode
Battery: Lithium battery 7.4V4Ah
Adapter: voltage 100-240VAC Current 0.1A Frequency 50-60Hz.
● 2 RS232 ports
● Operating temperature: -10℃-40℃, relative humidity is below 85 %
● Storage temperature: -20℃-60℃, relative humidity is below 85 %
● Conforming to standard :GB/T 7724-1999
2
、
Main Function
● Basic weighing function: resetting, removing the peel and clearing the peel
● Weight detection function, counting function, animal scale function
● Weight keeping function, weight accumulation function, percentage
display
● Set redundant backup function of parameters
● Automatic screen protection and automatic shutdown energy-saving
function
● Rich printing formats and communication protocol

4
3
、
Boundary Dimension
Instrument size: detailed in the following figure (mm); instrument weight:
1.5kg
4
、
Connector
4.1 RS232-1 and RS232-2
2Pin: TXD 3Pin: RXD 5Pin: GND

5
4.2 Load cell Connector
1Pin: +E 2Pin: +S 3Pin: SHLD 4Pin: -S
5Pin: +E
5
、
Introduction to Panel
● Introduction to indicator lamps
Identification
Analysis
Sorting and weight check status
indicator
Extension indicator
Counting scale indicator
Animal scale indicator
Accumulating scale indicator
Accumulating scale adjustment
display indicator
Weight hold indicator
Net weight indicator
Scale in dynamic status
Scale at zero indicator
Key pressed indicator
Battery indicator
Weight unit

6
Counting scale unit
Weight % indicator
`
● Introduction to operation keys
Operation without special specification refers to short press on keys.
Key
symbol
Normal weighing state
Set stage
Weight maintenance key->『Hold』
Short press→ F2.1 = 1, keep/cancel.
F2.1 = 2, switch between percentage and
weight.
F2.1 = 5, switch between quantity and
weight.
Long key→ enter setting menu.
Return to the
last menu.
Accumulation key->『Total』
Short key → F2.1 = 4, include display weight
in accumulation value.。
F2.1 = 0 ,enter into/exit the
accumulation model.
Long key → F2.1 = 3, select scale to sample
target weight.
F2.1 = 4, accumulate weight of
scale display.
F2.1 = 5, count sampling of scale.
No definition.
Printing key->『Print』
Short key → start up of print.
Flicker bit is on the
left.

7
Function key->『Func』
Long key → Enter into setting menu.
Flicker bit is on the
right.
Tare key->『Tare』
Short key →gross weight turns to net weight.
Indication lamp of net weight “Net” is on.
Conduct skin removal operation for multiple
times.
Digit flicker
position reduces.
ZERO Key->『Zero』
Gross weight state resets weight. When the
scale is in net weight, dynamic state, saving
state and out of resetting range, zero clearing
operation is invalid.
In setting, digit of
flicker position
increases. In
adjustment of display,
accumulation is
cleared.
Short key → Start up。
Long key → shut down.
Confirm operation,
to save setting
data.
6
、
Parameter Setting
Setting entry:
Press the 『Func』 button on the operating panel in the state of
normal weighing.
If F1.14 = 0, you can set all the parameters within F1~F5.
If F1.14 = 1, you can only set all parameters within F2~F5.
If F1.14 = 1 and you need to set the parameters within F1 menu, you
can press the calibration switch button until the F1 menu is entered.
F1 Parameter Setting
F1.1 Measuring Range
Selectable parameters: 3~200000 (default value: 6)
F1.2 Decimal Places
Selectable parameters: 0 ---- no decimal point
0.0 ---- 1 decimal place

8
0.00 ---- 2 decimal places
0.000 ---- 3 decimal places (default value)
0.0000 ---- 4 decimal places
F1.3 Number of Divisions
Selectable parameters: 1 (default value), 2, 5, 10, 20, 50
F1.4 Calibration Unit
Selectable parameters: 0 ---- kg (default value)
1 ---- lb
F1.5 Gravitational Acceleration
Selectable parameters: 9.70000~9.99999. Default value = 9.79455.
F1.6 Null-point Calibration
【 】 Keeping empty the scale
Remove the weights on the weighing platform
to guarantee the scale is in the empty state.
Press the『ON/OFF』。key and the indicator will
display【】,The displayed digits will
reduce slowly until the indicator displays
【】,In the end it will display【 】
for one second, which indicates the end of
null-point calibration.
F1.7 Load-point Calibration
【 】 Loading weights
Load weights on the weighing platform to ensure
that 10% of full-scale value ≤ weight of weights
≤ full-scale value, and then press the『ON/OFF』
key to start the next step.
【 】 Entering the same weight value as that of the
loaded weights.
Entering the same weight value as that of the
loaded weights, please press the『ON/OFF』key
after the scale becomes stable, and the meter
will display [ ]. After that, the displayed
digits will reduce slowly until the meter displays

9
[ ]. In the end it will display [ ] for
one second, which indicates the end of
null-point calibration.
F1.8 Automatic Null Tracking
Selectable parameters: OFF, 1 d, 2 d, 3 d, 5 d (default value)
F1.9 Automatic Reset Range at Startup
Selectable parameters: OFF, 2 %, 10 %, 20 % (default value)
F1.10 Button Reset Range
Selectable parameters: OFF, 2 %, 10 % (default value), 20 %
F1.11 Digital Filter
Selectable parameters: 0 ---- Mild Filtering
1 ---- Moderate Filtering (default value)
2 ---- Severe Filtering
F1.12 Steady Range
Selectable parameters: 1 d, 2 d, 3 d (default value)
F1.13 Overload Display Range
Selectable Parameters: 9d, 5% (default value), 10%, 20% ±120%
F1.14 F1 Menu Protection
Selectable Parameters: 0 ---- Enter F1 menu by keyboard
operation
1 ---- Enter F1 menu by pressing the calibration button
F1.15 Strong filter mode
Selectable Parameters:0 ---- Not enabled
1 ---- start using
F1.16 Restoring Factory Default
Set the parameters within F1~F4 as the defaults, which can’t
impact the parameters of standard scale.
F2 Application Function Setting
F2.1 Function Selection
Selectable Parameters: 0 ---- ×10 functions