SIC GTB6L Bedienungsanleitung

Described product
G6L
GTB6L
Manufacturer
SICK AG
Erwin-Sick-Str. 1
79183 Waldkirch
Germany
Production location
SICK Malaysia
Legal information
This work is protected by copyright. Any rights derived from the copyright shall be
reserved for SICK AG. Reproduction of this document or parts of this document is
only permissible within the limits of the legal determination of Copyright Law. Any modi‐
fication, abridgment or translation of this document is prohibited without the express
written permission of SICK AG.
The trademarks stated in this document are the property of their respective owner.
© SICK AG. All rights reserved.
Original document
This document is an original document of SICK AG.
Laser
1
2006/42/EC
NO
SAFETY
OPERATING INSTRUCTION
8025391.1CGF/2021-07-13 | SICK O P E R A T I N G I N S T R U C T I O N | GTB6L 3
Subject to change without notice
en

Contents
1 About this document............................................................... 5
2 Safety information................................................................... 6
3 Product description................................................................. 7
4 Mounting.................................................................................. 8
5 Electrical installation............................................................... 8
6 Commissioning........................................................................ 10
7 Troubleshooting....................................................................... 12
8 Disassembly and disposal...................................................... 13
9 Maintenance............................................................................ 13
10 Technical specifications.......................................................... 14
11 Annex........................................................................................ 15
OPERATING INSTRUCTION
4O P E R A T I N G I N S T R U C T I O N | GTB6L 8025391.1CGF/2021-07-13 | SICK
Subject to change without notice
en

1 About this document
1.1 Further information
You can find the product page with further information under the SICK Product ID at:
pid.sick.com/{P/N}.
P/N corresponds to the part number of the product.
The following information is available depending on the product:
•Data sheets
•These publication in all available languages
•CAD files and dimensional drawings
•Certificates (e.g., declaration of conformity)
•Other publications
•Software
•Accessories
1.2 Symbols and document conventions
Warnings and other notes
DANGER
Indicates a situation presenting imminent danger, which will lead to death or serious
injuries if not prevented.
WARNING
Indicates a situation presenting possible danger, which may lead to death or serious
injuries if not prevented.
CAUTION
Indicates a situation presenting possible danger, which may lead to moderate or minor
injuries if not prevented.
NOTICE
Indicates a situation presenting possible danger, which may lead to property damage if
not prevented.
NOTE
Highlights useful tips and recommendations as well as information for efficient and
trouble-free operation.
Instructions to action
bThe arrow denotes instructions to action.
1. The sequence of instructions is numbered.
2. Follow the order in which the numbered instructions are given.
✓The tick denotes the results of an action.
OPERATING INSTRUCTION
8025391.1CGF/2021-07-13 | SICK O P E R A T I N G I N S T R U C T I O N | GTB6L 5
Subject to change without notice
en

2 Safety information
2.1 General safety notes
Connection, mounting and configuration of the product must only be car‐
ried out by qualified personnel.
2006/42/EC
NO
SAFETY
This product does not constitute a safety component as defined in the
Machinery Directive.
Do not install the product in places exposed to direct UV radiation (sun‐
light) or other weather conditions.
The product must be adequately protected against moisture and contami‐
nation.
Laser notes
CAUTION
Interference, manipulation or incorrect use can lead to hazardous exposure due to laser
radiation.
The emitted light beam must not be focused by means of additional optical devices.
LASER
1
Figure 1: Laser class 1
This device complies with the following standards:
•EN/IEC 60825-1:2014
•21 CFR 1040.10 and 1040.11 except for tolerances according to Laser Notice No.
56 dated May 8, 2019.
The laser is eye-safe.
The laser marking is located on the housing imprint on the sensor.
■Read the operating instructions before commissioning.
■
Connection, mounting, and configuration may only be performed by trained
specialists.
■
2006/42/EC
NO
SAFETY
Not a safety component in accordance with the EU Machinery Directive.
■
Do not install the sensor at locations that are exposed to direct sunlight
or other weather influences, unless this is expressly permitted in the operating
instructions.
■When commissioning, protect the device from moisture and contamination.
■These operating instructions contain information required during the life cycle of
the sensor.
OPERATING INSTRUCTION
6O P E R A T I N G I N S T R U C T I O N | GTB6L 8025391.1CGF/2021-07-13 | SICK
Subject to change without notice
en

EN/IEC 60825-1:2014
LASER CLASS 1
Laser
1
Maximum pulse power < 5.95 mW
Puls length: 2 µs
Wavelength: 670 - 690 nm
Complies with FDA performance
standards except for conformance with
IEC 60825-1 Ed. 3,
as described in Laser Notice No. 56,
dated May 8, 2019
ATTENTION
WARNING: Interruption, manipulation or incorrect use can lead to hazardous exposure
due to laser radiation.
2.2 Intended use
The GTB6L is an opto-electronic photoelectric proximity sensor (referred to as “sensor”
in the following) for the optical, non-contact detection of objects. If the product is used
for any other purpose or modified in any way, any warranty claim against SICK AG shall
become void.
3 Product description
3.1 Operating and status indicators
Photoelectric proximity sensor with background suppression.
GTB6L-xxx1x
1
2 3 23
1
1Potentiometer: sensitivity adjustment
2Yellow LED: status of received light beam
3Green LED: Supply voltage active
GTB6L-xxx3x
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
OPERATING INSTRUCTION
8025391.1CGF/2021-07-13 | SICK O P E R A T I N G I N S T R U C T I O N | GTB6L 7
Subject to change without notice
en

2 3 23
4 Mounting
Mount the sensorusing a suitable mounting bracket (see the SICK range of accesso‐
ries).
Note the preferred orientation of the sensor relative to the direction of object motion,
refer to figure 2.
Figure 2: Sensor orientation relative to object direction
5 Electrical installation
The sensors must be connected in a voltage-free state (UV = 0V). The following informa‐
tion must be observed depending on the connection type:
– Plug connection: pin assignment
– Cable: wire color
Only apply voltage/switch on the voltage supply (UV >0V) once all electrical connec‐
tions have been established.
Explanation of connection terminology:
BN = Brown
WH = White
BU = Blue
BK = Black
n. c. = no connection
Q = switching output 1
Q = switching output 2
OPERATING INSTRUCTION
8O P E R A T I N G I N S T R U C T I O N | GTB6L 8025391.1CGF/2021-07-13 | SICK
Subject to change without notice
en

L+ = supply voltage (Uv)
M = common
L.ON = light operate
D.ON = dark operate
Connection and Output detail:
Table 1: DC
GTB6L -P1xxx
-N1xxx
-E2xxx
-F2xxx
-P3xxx
-N3xxx
-P5xxx
-N5xxx
-P4xxx
-N4xxx
-P6xxx
-N6xxx
-P7xxx
-N7xxx
-E4xxx
-F4xxx
-E6xxx
-F6xxx
-E7xxx
-F7xxx
1 = BN + (L+) + (L+) + (L+) + (L+) + (L+)
2 = WH -Q- n. c. Q
3 = BU - (M) - (M) - (M) - (M) - (M)
4 = BK Q Q Q Q Q
0.205 mm2 /
AWG24 0.205 mm2 /
AWG24
4
3 1
4
3
2
1
4
3
2
1
Table 2: Output function
GTB6L
-Px1xx
-Px2xx
-Px3xx
-Px4xx
L.ON, PNP: Q (≤ 100mA)
+ (L+)
Q
‒ (M)
Load
+ (L+)
Q
‒ (M)
Load
-Px1xx
-Px2xx
-Px5xx
-Px6xx
D.ON, PNP: Q (≤ 100mA)
+ (L+)
Q
‒ (M)
Load
+ (L+)
Q
‒ (M)
Load
-Nx1xx
-Nx2xx
-Nx3xx
Nx4xx
L.ON, NPN Open Collector Q (≤ 100mA)
+ (L+)
Q
‒ (M)
Load
+ (L+)
Q
‒ (M)
+ (L+)
Q
‒ (M)
Load
OPERATING INSTRUCTION
8025391.1CGF/2021-07-13 | SICK O P E R A T I N G I N S T R U C T I O N | GTB6L 9
Subject to change without notice
en

-Nx1xx
-Nx2xx
-Nx5xx
-Nx6xx
D.ON, NPN Open Collector Q (≤ 100mA)
+ (L+)
Q
‒ (M)
+ (L+)
Q
‒ (M)
Load
+ (L+)
Q
‒ (M)
Load
5.1 Notes on UL approval
The device shall be supplied from an isolating transformer having a secondary overcur‐
rent protective device that complies with UL 248 to be installed in the field rated either:
a) max 5 amps for voltages 0 ~ 20 V (0 ~ 28.3 V peak), or
b) 100 / Vp for voltages of 20 ~ 30 V (28.3 ~ 42.4 V peak).
Alternatively, they can be supplied from a Class 2 power supply.
UL Environmental Rating: Enclosure type 1
6 Commissioning
6.1 Alignment
Align sensor on object. Select the position so that the red emitted light beam hits the
center of the object. You must ensure that the optical opening (front screen) of the
sensor is completely clear [see figure 3].
Figure 3: Alignment
6.2 Sensing range
Adjust the mounting position to ensure the sensing range and the background are
within the specifications. See see figure 4, page 11.
NOTE
Observe the minimum distance of 5mm.
Check the function as described in see table 2, page 9. If the switching output fails to
behave as described in see table 2, page 9, check the application conditions.
Minimum distance in mm (y) between the set sensing range (x) and white background
(90% remission):