L88 Amber – Manual
WAM488AmberA 2 Standby AB – standbygroup.se
Flash Pattern
Introduction
The flash pattern setting controls the flash pattern. There are five versions of flash pattern: Double,
Triple, Steady burn 1, Steady burn 2 and Indicator.
Double and Triple are built-in flash patterns and no control system is needed.
With Steady burn 1 and Steady burn 2 an external flasher or control system is used to
control the flash pattern.
With Indicator the lamp is controlled by the direction indicator system.
The factory setting of flash pattern is Double.
When in configuration mode, the number of blank flashes (lamp off) in the flash sequence show the
current flash pattern setting, see table.
Blank flashes per
flash sequence Flash pattern Flash control
1 Double Built-in
2 Triple Built-in
3 Steady burn 1 External
4 Steady burn 2 External
5 Indicator Direction indicator system
Setting the Flash Pattern
WARNING
Risk of eye damage. Do not look into the beam at close range.
WARNING
Hot surfaces. Do not touch the cooling flanges when the lamp is on.
1. If already in configuration mode, go to step 6.
2. If the lamp is connected to the power supply, disconnect it.
3. Connect the red wire to 10-30 V DC via a 5 A fuse.
!
!