Time Electronics 7007 Loop-Mate 2 Bedienungsanleitung

User Manual
7007 Loop-Mate 2
Loop Signal Indicator
Version 1.1
August 2021
Time Electronics Ltd
Unit 5, TON Business Park, 2-8 Morley Road,
Tonbridge, Kent, TN9 1RA, United Kingdom.
T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198
mail@timeelectronics.co.uk | www.timeelectronics.com

© 2021 Time Electronics Ltd.
All rights reserved.
Nothing from this manual may be multiplied, or made public in any form or manner, either
electronically or hard copy, without prior written consent from Time Electronics Ltd.
This also applies to any schematics, drawings and diagrams contained herein.
This manual provides operating and safety instructions for the Time Electronics product.
To ensure correct operation and safety, please follow the instructions in this manual.
Time Electronics reserves the right to change the contents, specifications and other
information contained in this manual without notice.

Time Electronics User Manual
7007 Loop-Mate 2 Loop Signal Indicator v1.1
7007 Loop-Mate 2 Loop Signal Indicator Page 3 of 25
Contents
1Introduction....................................................................................................................................4
1.1 Features ................................................................................................................................................ 4
1.2 Description.............................................................................................................................................5
1.3 Specifications ........................................................................................................................................6
2Front panel controls......................................................................................................................7
3Operation........................................................................................................................................8
3.1 Function Select......................................................................................................................................8
3.2 Display Select........................................................................................................................................8
3.3 Description of typical process loop components....................................................................................8
3.4 Rx Sim function ...................................................................................................................................10
3.5 Tx Test function...................................................................................................................................11
3.6 Meas Volt DC function.........................................................................................................................12
4Power supply ...............................................................................................................................13
4.1 Battery life............................................................................................................................................ 13
4.2 Battery replacement ............................................................................................................................ 13
5Maintenance................................................................................................................................. 14
5.1 Calibration ...........................................................................................................................................14
5.2 Adjustment of Calibration .................................................................................................................... 18
6Warranty and Servicing............................................................................................................... 24

Time Electronics User Manual
7007 Loop-Mate 2 Loop Signal Indicator v1.1
7007 Loop-Mate 2 Loop Signal Indicator Page 4 of 25
1Introduction
1.1 Features
•4 - 20 mA, 0 -10 V, 0 - 50 V ranges
•LCD 4 digit display, mA, V, % of range
•Accuracy 0.05 %
•RxSim, TxTest, or 50 mA / 50 V modes
•Internal loop supply, 25 mA max
•Battery powered 9 V PP3
•Supplied with carry case and test leads

Time Electronics User Manual
7007 Loop-Mate 2 Loop Signal Indicator v1.1
7007 Loop-Mate 2 Loop Signal Indicator Page 5 of 25
1.2 Description
The 7007 LoopMate 2 is a dedicated loop signal indicator (RxSim) with an in-built 24 V loop
drive supply (TxTest). The operator can select the loop type, and also the type of units,
either direct (mA) or % of span display. The loop signal is shown on an easy-to-read LCD
display to an accuracy of 0.05% either in mA, V, or % of span.
It is a cost-effective process instrument suitable for service and maintenance engineers. It
combines simple operation with the accuracy required for most process applications. Used in
conjunction with the 7006 LoopMate 1 they provide full process loop testing capabilities,
facilitating quick location of faults, testing and re-calibration.
In addition to TxTest (transmitter test) and RxSim (receiver simulation) the 7007 can be used
to measure DC voltage in the process loop up to 50 V.
The unit is powered by a PP3 type battery. Rechargeable batteries can be used if required.
It comes complete with carrying pouch, leads and user manual.

Time Electronics User Manual
7007 Loop-Mate 2 Loop Signal Indicator v1.1
7007 Loop-Mate 2 Loop Signal Indicator Page 6 of 25
1.3 Specifications
Functions RxSim, TxTest, Meas Volt DC.
Ranges
RxSim:0 to 50 mA or 0% to 100% (4-20mA).
TxTest (RxSim plus internal 24V DC loop drive): 0 to 25 mA or 0% to 100% (4-20mA).
Meas Volt DC: 0 to 50 V DC or 0% to 100% (0 to 10 V).
Accuracy
0.05% of Span (% of span)
0.05% of Range (mA/V).
Indication 4.5 digit LCD display
Connections Two 4 mm recessed sockets
Power PP3 battery
Case Material ABS plastic
Carrying Pouch Leatherette material. Includes compartment for leads and spare battery.
Leads 4mm gold plated connectors.
Temperature Co-efficient The unit stays in specification over operating temperature range.
Operating Temperature 0 to 50 °C.
Storage Temperature -30 to 70 °C.
Operating Humidity 10 to 90% non-condensing, 25 °C.
Dimensions H 140 x W 65 x D 27 mm (6.0 ×2.5 ×1.0 in).
Weight 200 grams (7 oz).
Options
C145: Traceable calibration certificate (Factory).
C144: Accredited calibration certificate (ISO 17025).
7006: Loop-Mate 1: Loop Simulator (separate product).

Time Electronics User Manual
7007 Loop-Mate 2 Loop Signal Indicator v1.1
7007 Loop-Mate 2 Loop Signal Indicator Page 7 of 25
2Front panel controls
Connection Terminals
Display Switch
LCD Display
Function Switch

Time Electronics User Manual
7007 Loop-Mate 2 Loop Signal Indicator v1.1
7007 Loop-Mate 2 Loop Signal Indicator Page 8 of 25
3Operation
3.1 Function Select
The Loop-Mate 2 has 3 functions:
1. Function 1 ..................Rx SIM
2. Function 2 ..................Tx TEST
3. Function 3 ..................Meas Volt DC
These are selected using the function select switch.
3.2 Display Select
For RxSim and TxTest the signal can be displayed either direct (mA) or % of span.
These are selected using the display select switch, which also turns off the Loop-Mate 2.
3.3 Description of typical process loop components
4 - 20 mA process loop
0 - 10 V process loop
4-20 mA Process loop
and
4 - 20 mA Control loop.
This can be used for
closed loop control.

Time Electronics User Manual
7007 Loop-Mate 2 Loop Signal Indicator v1.1
7007 Loop-Mate 2 Loop Signal Indicator Page 9 of 25
Tx (transmitter):
This component converts physical signals such as pressure, temperature, flow, and level
etc, into the loop signals (4 - 20 mA or 0 - 10 V).
Rx (receiver):
This component measures the loop signal and either displays it (indicator) or converts it to
another form e.g. digital output for control purposes, (controller).
Process Controllers:
This device usually contains both Rx (signal loop) and Tx (control loop) components, which
operate in separate loops. The Rx and Tx can be either 4 - 20 mA or 0 - 10 V.
Loop excitation supply:
A DC power supply (nominally 24 V) that drives the loop.

Time Electronics User Manual
7007 Loop-Mate 2 Loop Signal Indicator v1.1
7007 Loop-Mate 2 Loop Signal Indicator Page 10 of 25
3.4 Rx Sim function
The unit displays the loop current in either mA (0-50 mA) or percentage of span (4-20 mA),
depending on the position of the display select switch.
3.4.1 Operation
1. Connect the unit to the process loop observing the correct polarity.
2. Set the function switch to RxSim.
3. Turn the unit on, selecting the desired display units, using the display switch.
Note: If the loop current is less than 4 mA, negative % of span will be displayed.
See table below.
3.4.2 Connection
excitation
supply
Loop
RxSim
+ve
-ve
Loop-Mate2
Tx
(Transmitter)
4-20mA
Loop Current (mA)
Display Reading
Open Circuit -25.00
1 -18.75
2
-12.50
3
- 06.25
4
00.00
Inhaltsverzeichnis
Andere Time Electronics Messgerät Handbücher

Time Electronics
Time Electronics 1044 Bedienungsanleitung

Time Electronics
Time Electronics 7006 Bedienungsanleitung

Time Electronics
Time Electronics 1021 Bedienungsanleitung

Time Electronics
Time Electronics 1006 Bedienungsanleitung

Time Electronics
Time Electronics 1090 Bedienungsanleitung

Time Electronics
Time Electronics 1049 Bedienungsanleitung

Time Electronics
Time Electronics 7078 Bedienungsanleitung

Time Electronics
Time Electronics 5011 Bedienungsanleitung

Time Electronics
Time Electronics 1070 Bedienungsanleitung

Time Electronics
Time Electronics 9762 Bedienungsanleitung