Owner’s Manual #513642 Rev.4 2 CC Model Machines
1.2 SPECIFICATIONS
CC202A Air Cooled Remote CC202A Water Cooled
Dimensions Machine with crate Machine with crate
width 25-1/2’’ (64,8 cm) 48’’ (121,9 cm) 25-1/2’’ (64,8 cm) 48’’ (121,9 cm)
height 61-7/8’’ (157,2 cm) 68’’ (172,7 cm) 61-7/8’’ (157,2 cm) 68’’ (172,7 cm)
depth 47-1/8’’ (119,7 cm) 60’’ (152,4 cm) 47-1/8’’ (119,7 cm) 60’’ (152,4 cm)
Weight 1030 lbs (467,2 kg) 1100 lbs (498,9 kg) 1030 lbs (467,2 kg) 1100 lbs (498,9 kg)
Electrical 1 Phase, 208-240 VAC,
60Hz
3 Phase, 208-240
VAC, 60Hz
1 Phase, 208-240 VAC,
60Hz
3 Phase, 208-240
VAC, 60Hz
circuit ampacity
(per barrel) 12A minimum 9A minimum 28A minimum 21A minimum
overcurrent protection
device (per barrel) 25A maximum 15A maximum 45A maximum 30A maximum
Hopper Condensing
Unit
1 Phase, 115 VAC, 60Hz
NEMA5-15P power cord provided
Compressor Freezing Cylinders - 9,800 Btu/hr
Storage - 2,760 Btu/hr Compressor (R-134a)
Drive Motor Two - 3 hp
Cooling
Air cooled units require one remote
condensing unit (with compressor) per
barrel. The condensing units ship from the
factory with 20 lbs of R-404A for up to a
50’ line set. Add 1 lb of refrigerant for every
10’ increase to the line set. Line set max
100’.
Water cooled units are self contained
and require 1/2” N.P.T. water and drain
fittings. Maximum water pressure of 130
psi. Minimum water flow rate of 3 GPM per
barrel. Ideal EWT of 50°-70°F. They are
charged with R-404A.
Hopper Volume Two - 8.8 gallon (33,32 liters)
CC303A Air Cooled Remote CC303A Water Cooled
Dimensions Machine with crate Machine with crate
width 32-1/2’’ (82,6 cm) 48’’ (121,9 cm) 32-1/2’’ (82,6 cm) 48’’ (121,9 cm)
height 61-7/8’’ (157,2 cm) 68’’ (172,7 cm) 61-7/8’’ (157,2 cm) 68’’ (172,7 cm)
depth 47-1/8’’ (119,7 cm) 60’’ (152,4 cm) 47-1/8’’ (119,7 cm) 60’’ (152,4 cm)
Weight 1095 lbs (496,6 kg) 1165 lbs (528,4 kg) 1095 lbs (496,6 kg) 1165 lbs (528,4 kg)
Electrical 1 Phase, 208-240 VAC,
60Hz
3 Phase, 208-240
VAC, 60Hz
1 Phase, 208-240 VAC,
60Hz
3 Phase, 208-240
VAC, 60Hz
circuit ampacity
(per barrel) 12A minimum 9A minimum 28A minimum 21A minimum
overcurrent protection
device (per barrel) 25A maximum 15A maximum 45A maximum 30A maximum
Hopper Condensing
Unit
1 Phase, 115 VAC, 60Hz
NEMA5-15P power cord provided
Compressor Freezing Cylinders - 9,800 Btu/hr
Storage - 2,760 Btu/hr Compressor (R-134a)
Drive Motor Three - 3 hp
Cooling
Air cooled units require one remote
condensing unit (with compressor) per
barrel. The condensing units ship from the
factory with 20 lbs of R-404A for up to a
50’ line set. Add 1 lb of refrigerant for every
10’ increase to the line set. Line set max
100’.
Water cooled units are self contained
and require 1/2” N.P.T. water and drain
fittings. Maximum water pressure of 130
psi. Minimum water flow rate of 3 GPM per
barrel. Ideal EWT of 50°-70°F. They are
charged with R-404A.
Hopper Volume Three - 8.8 gallon (33,32 liters)