SDP134T Whale INSTANT MATCH® with Bluetooth®wireless technology Kit
300,000
WHALE KITS INSTALLED IN THE UK
Please leave this booklet with the end user
after installation and demonstration

umbing of the Waste Pipe
umbing of the Waste Pipe
User Warnings
• This appliance may be used by children from 8 years and above, by persons with reduced physical, sensory
or mental capabilities and by persons who lack experience of the system, if they have been given instructions
concerning the use of the application in a safe way and they understand the hazards involved. Children shall not
play with the appliance. Cleaning and user maintenance shall not be carried out by children without supervision.
• If any components or cords are damaged, it must be replaced by a qualified person to avoid a hazard.
End User Help
1. y pump is turning on but not taking the water away
Please contact a plumber to check for blockages, air leaks, and also the condition of the internal rubber
components. For video assistance on how to inspect and change the rubber components, please visit
www.whalepumps.com/psd. For further assistance or to request a new tricuspid valve please contact our
Technical Helpline on 0845 0694 253.
2. y pump is not working
Please turn on your shower and listen to or feel for vibration of the pump as it starts. If you hear or feel your
pump turn on please contact a plumber to check for blockages or air leaks in the pipework, and the condition of
the internal rubber components. For video assistance on how to check the pipework for issues and for a video
instructing you how to inspect and change the pump components, please visit www.whalepumps.com/psd.
If your pump doesn’t turn on. First check the power is on at the fused spur. If on, please contact an electrician
to inspect the power to the pump, or contact our Technical Helpline on 0845 0694 253 for further assistance.
3. y Pump is running slow/labouring/cutting out
Contact a plumber to check for blockages. If there are no blockages then contact our Technical Helpline
on 0845 0694 253 for further assistance.
4. y pump is constantly running
Please contact our Technical Helpline on 0845 0694 253 for further assistance before contacting an electrician
to carry out tests on the equipment.
5. y pump isn’t turning on
If your pump doesn’t turn on check that the power is turned on at the fused spur. If on, please contact an
electrician to inspect the power to the pump. For further assistance please contact our Technical Helpline
on 0845 0694 253
6. How do I register my warranty?
Please complete and return the warranty registration form supplied with your pump,
or complete the online form at: www.whalepumps.com/psd
0845 0694 253
info@whalepumps.com
www.whalepumps.com/psd
@Whalecare
Whale, 2 Enterprise oad,
Bangor, Co. Down,
BT19 7TA, N.Ireland
WARNING

Thank you for purchasing this Whale Instant atch® Bluetooth®
wireless technology product. Whale®is the market leader in pumped
shower drainage kits. These kits have the reputation of working reliably
for many years without requiring maintenance.
The front cover shows the product installation in an apartment with the components in a concealed access.
Assess your installation prior to fitting to ensure that the unit will be situated in an accessible location.
Typical installations would have these components in an adjacent cupboard i.e. airing cupboard or in a false
wall with an access panel. Do not fit the pump cover in these locations.
Incorrect installation may invalidate the warranty.
Principles of Operation
This kit has been designed for the pumping of shower waste water. The Whale Instant Match® with Bluetooth® wireless
technology control unit uses the flow signal from the shower to measure the flow rate of water into the shower. The
control unit uses the signals sent from the flow sensor to adjust the pump speed to match the flow of water from the
shower. This minimises suction noise at the gulley. When the shower is turned off, the flow sensor sends a signal to
the control unit and after a pre-set time delay the pump turns off. After a further 15 minutes the pump will automatically
switch on for a short period of time at a reduced pumping speed, removing any run off water pooled in the shower area.
The pump has the ability to run dry without causing damage. Non-return valves in the pump head prevent smells
entering the bathroom area from the waste pipe.
Installation Warnings
Before installation please read the instructions. All electrical and mechanical components (transformer and pump) must
be accessible after installation.
• The Whale Instant Match® with Bluetooth® wireless technology is designed to work on shower bases with a minimum
of a 1:40 fall to the gulley. Where the fall is insufficient, the water will not refill the gulley rapidly enough and so suction
noise will be increased. We recommend the use of a shower former as this eliminates the risks of pooling caused by
insufficient fall to the gulley.
• Forming a shower base by hand is a highly skilled task and should be carried out by a trained installer. Do not
attempt this if you are unsure and seek professional advice.
• The maximum flow rate of the shower that the pump is designed to work with is 8 ltrs/min.
• Avoid plumbing the pump outlet into the waste piping that other appliances drain into as there is a risk of
induced syphoning. Use an anti-syphon trap in these situations. (See page 7)
• In installations where the floor is being formed in the screed, we recommend the following minimum falls:
40mm in 1m, 20mm in 500cm,10mm in 250cm.
• Plumbing must comply to latest WRAS standards.
• The electrical wiring must conform to EU wiring regulations BS7671:2008 Part 7 (17th Edition).
• Pipework must be secured to prevent vibration and noise.
• Ensure that the water fall from the shower head is as close to the gulley as possible.
WARNING
3

lumbing of the Waste Pipe
User warnings 2
End user help 2
Principles of operation 3
Plumbing specication 5
Plumbing gulley 6
Plumbing of waste pipe 7
Installation 8
Transformer settings 11
Bluetooth®wireless technology setup 12
Bluetooth®wireless technology unpairing 15
Hardwired setup 16
Purge cycle 18
Swapping pump & transformer on backplate 18
Safety warning 18
Installation testing and repair 19
EU declaration of conformity 20
Statement of limited warranty 20
Specication 21
List of parts included in the kit 22
Spare and Accessories 22
Fault diagnosis 24/25
Product dimensions 26/27
Index

Maximum pipe length is 3m
from gulley to pump. Pipe from
gulley to pump must be in 15mm.
MIN 1:40 FALL (Do not use 22mm pipework for
electric showers. This will increase gulley noise.)
GULLEY
3M (MAX)
TRAY
15MM DIA PIPE
USE ONLY 22MM
PIPE ON THE
PUMP OUTLET
0.2 M (MIN)
0.4 M (MAX)
FORMED
BEND
1M (MAX)
WASTE PIPE
HORIZONTAL TO WASTE PIPE
TO INCREASE PUMP LIFE ENSURE THAT 32mm ( 1 1/4")
or 40mm (1 1/2") PIPE IS USED WITH A GRAVITY
FALL WHERE THE PIPE LENGTH IS GREATER THAN 1M.
IF LESS THAN 1M USE 22MM PIPE
WARNING
WARNING
• The Whale®pump is IP45 compliant. Locate pump in
accordance with BS7671: 2008 Part 7 (17th Edition).
The pump may be installed in bathroom zones 1, 2 or 3.
• Maximum flow rate 8 ltrs per min.
• Unit and Flow Sensors MUST BE ACCESSIBLE AFTE INSTALLATION.
• Use slow radius bends where possible. Full size elbows are acceptable,
not stem or Male/Female elbows. Where possible avoid attaching elbows
directly to the pump.
• Inserts MUST NOT be used with plastic pipe.
• Please use the push fit fittings supplied with the kit. Ensure the pipe
is pushed fully home into the fittings and secured by the 'twist lock'.
Use silicon spray to aid pipe insertion in order to prevent the 'O' ring
being displaced or rolled.
• Ensure pipe edges are score free. Do not use a hacksaw to cut pipe.
• Use one vertical lift to the pump and one vertical rise from the pump.
Pipework must be secured.
0.5 M
(MAX)
5
Fig 1.1
Plumbing Specification

umbing of the Waste Pipe
• Rotate the pump head if necessary. Loosen clamping ring screw,
rotate and retighten as shown. See Fig 1.2
• Before commissioning the shower and running water through the
system, ensure that the shower area and gulley are completely free
of building debris, especially tile grout, screed material and latex.
Plumbing Gulley
• Do not use inserts or stem elbows as these restrict flow.
• When fitting in solid floors if copper pipe is used, it must be
sheathed to prevent corrosion.
• Orientate gulley so that it exits towards the pump inlet to avoid
unnecessary bends.
Wet Floor Gulley:
The wet floor gulley has a 40mm profile to enable it to fit into a screed
floor without penetrating the damp-proof membrane. See Fig 1.3
• Where a floor former is not used, the gulley has two lugs either side of
the discharge pipe to enable the gulley to be fixed to the floor whilst
screed is laid.
• Where a floor former is used, these lugs can be easily broken off to
enable it to be fitted.
• The gulley has a conventional clamping ring to accommodate vinyl
flooring.
• Once the area has been cleaned and before the shower is lined,
remove dust seal and click cover into place.
Tray Gulley:
The tray gulley has a 35mm profile to enable it to fit into a screed floor
without penetrating the damp-proof membrane. See Fig 1.4
• Use the hand tool provided to tighten the locking flange and leave it in
place to keep debris out of gulley. Only remove it and fit the gulley cover
when the shower area has been cleaned. See Fig 1.4
• Ensure that the gulley debris grid provided is fitted before the shower
is used. See Fig 1.4
Fig 1.2
Fig 1.3
Fig 1.4

Plumbing of the Waste Pipe
Plumbing of the Waste Pipe
The outlet of the pump can be connected into the waste
pipe, e.g. existing bath waste. Black rubber fittings are
provided for this.
• In confined bathrooms the pump discharge may go into
the sink waste pipe using suitable adaptors. See Fig 1.5
for 32mm (1 1/4") McAlpine examples and the McAlpine
catalogue for other variants.
Use with a Macerator Pump
• Discharge from the Whale®pump must go into the top
of the macerator box. Do not use the bottom entries.
See Fig 1.6
• It is preferable to have two separate discharge lines to
waste as any failure of the macerator will not be
detected by the Whale pump.
Fig 1.6
Fig 1.5
22mm
V33T
32mm
(1 1/4")
A10V
32mm
(1 1/4")
Macerator Pump
7

• Run 15mm pipe from gulley to pump inlet (max 3m).
• Use slow radius bends where possible. Full size elbows
are acceptable, not stem or Male/Female elbows. Where
possible avoid attaching elbows directly to the pump.
2. Locating your pump on the wall
• Select a suitable location for the pump, considering
the best plumbing option for the pump outlet to
discharge into the waste pipe. The pump head may
be rotated to the left hand side or right hand side.
• Mount square to wall.
• Using a spirit level ensure that the unit is mounted level.
• Do not install the pump inlet/outlet more than
500mm off the floor.
• NOTE: The pump and transformer mounting location
on the backplate may be swapped right to left / left to
right. See Page 18 for further information.
1. Plumbing drainage pipe
Plumbing of the Waste Pipe
Installation

• Mark the hole centres through unit backplate.
• Drill holes in wall and fit wall plugs (if necessary).
Use 6mm masonry bit.
• Secure the backplate to the wall using
supplied screws.
• Use screw locations 1,2,3. Locations A and B
are optional.
3. ounting your pump to the wall
• Push the pipes into the fittings to the full depth of
insertion and secure by locking the fittings using
the "twist lock".
4. Plumbing connections
9
B
A

• Connect mains wire to a 5A fused spur.
• The transformer is factory set as shown to the right on
the jumper settings for Bluetooth®wireless technology
10 seconds overrun and 15mm inlet pipe size.
For other settings please refer to Transformer settings
(see page 11).
• Refit the hatch and tighten the screws to make
the transformer water resistant.
5. Wiring your transformer
• The blue LED flashes every 10 seconds indicating
that power is on.
• The green LED flashes when water is flowing
through the shower.
• When the test button is depressed the buzzer beeps.
6. The Whale Instant atch® with Bluetooth®
wireless technology transformer includes
Activelink diagnostics to aid installation:
On the transformer are two indicator LEDs
WITH