Contents
Introduction 3
Safety information 3
Precautionary symbols 3
Product components 3
Battery use and battery life 4
Charging the battery pack 5
Battery replacement 6
Connect the handheld to the cable assembly 8
ProDSS sensor installation/removal 9
Operation 13
Keypad and navigation 13
Startup 14
Navigation 14
Main display description 15
System menu 16
Sensor menu 22
Calibration menu 28
Files menu 29
Taking measurements 32
Calibration 33
Before calibration 33
Calibration setup (pH, ORP, ISE, conductivity, turbidity) 33
Conductivity 35
Barometer 36
Dissolved oxygen 37
pH/ORP 39
Depth 41
Turbidity 42
ISEs: Ammonium, Nitrate, & Chloride 44
Maintenance and storage 51

II
ProDSS handheld instrument 52
Cable, bulkhead, and connectors 53
Sensor guard 53
Depth sensor maintenance and storage 54
Turbidity sensor 55
Conductivity/temperature sensor 56
Dissolved oxygen sensor 57
pH - pH/ORP sensors 61
ISE sensors 63
KorDSS software installation 67
Install the KorDSS software 68
ProDSS driver installation 69
KorDSS startup wizard 72
Accessories 73
Ordering 73
ProDSS handhelds 74
ProDSS cable assemblies (No sensors included) 74
ODO/OBOD sensor and cable assemblies - DO/Temp only 75
ProDSS smart sensors 75
Replacement sensor modules and ODO sensor caps 75
ProDSS accessories 76
Calibration standards 77
Safety and support 79
Rechargeable Lithium-Ion battery pack safety warnings and precautions 79
Service information 81
Technical support 81
Declaration of Conformity 82
Warranty 84
Appendix A - DO% calibration values 85
Appendix B - oxygen solubility table 87

3
Introduction
Thank you for purchasing the YSI Professional Digital Sampling System (ProDSS).
ProDSS features include:
• Digital smart probes that are automatically recognized by the instrument when connected
• Waterproof (IP-67) case
• Long-life rechargeable lithium-ion battery pack
• Color display and backlit keypad
• User-selectable cable options
• USB connectivity
• Global Positioning System (GPS) (optional)
• Depth sensor (optional)
• Large memory with extensive site list capabilities
• Rugged enclosure with rubber over-molded case and miltary-spec (MS) connectors
Safety information
Please read this entire manual before unpacking, setting up or operating this equipment. Pay attention to all
precautionary statements. Failure to do so could result in serious injury to the operator or damage to the equipment.
Make sure that the protection provided by this equipment is not impaired. Do not use or install this equipment in any
manner other than that specified in this manual.
NOTICE: The manufacturer is not responsible for any damages due to misapplication or misuse of this product
including, without limitation, direct, incidental and consequential damages, and disclaims such
damages to the full extent permitted under applicable law. The user is solely responsible to identify
critical application risks and install appropriate mechanisms to protect processes during a possible
equipment malfunction.
Precautionary symbols
NOTE: Information that requires special emphasis
NOTICE: Indicates a situation which, if not avoided, may cause damage to the instrument
CAUTION: Indicates a potentially hazardous situation that may result in minor or moderate injury
WARNING: Indicates a potentially or imminently hazardous situation which, if not avoided, could result in death
or serious injury
Product components
Carefully unpack the instrument and accessories and inspect for damage. If any parts or materials are damaged,
contact YSI Customer Service at 800-897-4151 (+1 937 767-7241) or the authorized YSI distributor from whom the
instrument was purchased.
A

4
Introduction
Battery use and battery life
The ProDSS uses a rechargeable lithium-ion (Li-Ion) battery pack as a power source. The battery comes pre-installed in
the ProDSS and does not need to be replaced until the battery charge capacity is deemed unacceptable by the user.
The battery is shipped at ~50% full capacity and charging the battery is not required before first use.
Battery life depends on use, enabled parameters, LCD brightness, and GPS use. As with all lithium-ion batteries, battery
life will decline over time and use. This decay is typical and should be expected.
A new ProDSS battery is expected to last for the following durations (25 °C (77 °F), auto sampling, GPS on, keypad
backlight off):
• ProDSS instrument only - 48 hours
• ProDSS with fully loaded cable assembly and 25% (Default) LCD brightness - 20 hours
• ProDSS with fully loaded cable assembly and 100% LCD brightness - 14 hours
To increase battery life, enable manual sampling mode (Sampling on page 20). Manual sampling mode powers the
sensor/s on to take a measurement and then powers down to conserve battery life. Battery life may also depend on
the battery charging practices used. For maximum battery life, keep the battery 40% to 80% charged. Also, a larger
discharge (e.g. to 50%) is better than a small discharge (e.g. to 90%) between recharges.

5
Introduction
Charging the battery pack
A USB cable is included with the ProDSS to charge the instrument battery pack and connect the instrument to a PC.
The instrument battery pack can be charged from the AC power adapter, directly from a computer USB connection or
from an external, portable USB battery pack (sold separately, see ProDSS accessories on page 76).
Plug the USB connector into the AC power adapter, computer USB connector or external USB battery pack, then plug
the micro USB connector into the ProDSS instrument (Figure 1).
NOTE: The ProDSS internal charge controller only allows the battery pack to be charged if the temperature is
between 0 and 45 °C (32 and 113 °F).
WARNING: Charge the battery pack in an open area away from flammable materials, liquids, and surfaces. Read
Rechargeable Lithium-Ion battery pack safety warnings and precautions on page 79.
The ProDSS will charge faster when plugged into an AC outlet for charging rather than a PC’s USB port. For the
instrument to recognize that it is using AC power, you must start charging the ProDSS while on. After the instrument
recognizes it is being charged, it can be turned off to finish charging.
When using the AC adapter, it takes approximately 14 hours to charge the ProDSS battery when the instrument is
turned off during the charge. The amount of time required to completely charge the battery pack when the ProDSS is
initially turned on during the charge is approximately 9 hours.
Figure 1 Connecting the ProDSS to AC power supply
A

6
Introduction
Battery replacement
NOTE: The battery pack is pre-installed in the ProDSS instrument.
WARNING: Do not charge or handle a battery pack that is hot to the touch. Failure to follow the safety warnings
and precautions can result in personal injury and/or instrument damage not covered under
warranty. Read Rechargeable Lithium-Ion battery pack safety warnings and precautions on page
79.
1. Remove the battery pack cover by unscrewing (counter-clockwise) the four screws with a flat or Phillips head
screwdriver (Figure 2 on page 7).
NOTE: The retaining screws are captured into the battery pack cover and are not removable.
2. If replacing an existing battery pack, remove the Li-Ion battery pack and battery pack gasket/cradle. With two
fingers, grasp the battery pack connector and pull the connector straight up to disconnect and remove.
NOTE: Properly dispose of the old battery pack (Battery Disposal on page 80).
NOTE: A new gasket/cradle is included with a new battery pack to prevent water leaking into the instrument case.
When replacing the battery pack, use the new battery pack gasket/cradle supplied with the replacement
battery pack.
3. Inspect the replacement battery pack and battery pack gasket/cradle for damage. Contact YSI customer service
if the new battery pack and/or replacement gasket/cradle is damaged.
4. Correctly align and seat the battery pack gasket/cradle and battery pack into the instrument.
5. Align the battery pack connector wire terminals with the three instrument pins, then connect the battery pack to
the instrument.
NOTICE: Make sure that the three wire terminal connectors and three instrument pins are correctly aligned
before connecting the battery pack connector. Incorrect installation can damage the battery pack
connectors or instrument pins.
6. Install the battery pack cover, then tighten the cover screws. Make sure that the cover sealing surface is correctly
aligned and free of any contamination or damage.
NOTICE: Overtightening the cover screws can damage the battery cover.
A

7
Introduction
Figure 2 Battery replacement
1Battery pack cover 4 Instrument pin connectors
2Battery pack 5Battery pack gasket/cradle*
3Battery pack connector 6Battery pack gasket/cradle installed
*Color shown for reference
2
3
5
6
4
1

8
Introduction
Connect the handheld to the cable assembly
The ProDSS cable connectors are keyed for positive mating and to prevent connector damage (Figure 3). The ProDSS
instrument retains its IP-67 rating when the cable is disconnected. However, the connectors are not wet-mateable and
should be clean and dry before connecting.
Align the keys on the cable assembly connector with the slots on the instrument connector. Push together firmly, then
twist the outer ring clockwise until it locks into place.
Figure 3 Keyed connectors
1 Handheld female
connector
3 Keyed area of
connectors
2 Cable male connector
112223
1
2
3
Andere Handbücher für ProDSS
6
Inhaltsverzeichnis
Andere YSI Laborausrüstung Handbücher
Beliebte Laborausrüstung Handbücher anderer Marken

Agilent Technologies
Agilent Technologies 5800 ICP-OES Bedienungsanleitung

Endress+Hauser
Endress+Hauser Cleanfit CPA875 Bedienungsanleitung

NI
NI PXI-5422 Handbuch

Collomix
Collomix Aqix Bedienungsanleitung

SPEX SamplePrep
SPEX SamplePrep 6875 Freezer/Mill Series Bedienungsanleitung

Ocean Insight
Ocean Insight FLAME-NIR+ Bedienungsanleitung

Parker
Parker ALIGN-MG-NA Bedienungsanleitung

BD
BD 644787 Bedienungsanleitung

DENTAURUM
DENTAURUM Compact Megaplus Bedienungsanleitung

Biuged Laboratory Instruments
Biuged Laboratory Instruments BGD 626 Bedienungsanleitung

VWR
VWR SAS Super IAQ Bedienungsanleitung

illumina
illumina MiSeqDx Bedienungsanleitung