Date of Issue 11/12/2013 R6 Page 9of 58
8. Safe Mode
It is essential to ha e the trolley in a safe condition before any cleaning or maintenance takes place.
This is referred to in this manual as the SAFE MODE.
The trolley is in the SAFE MODE under the following conditions:
Fully isolated from any power source.
The cable, if supplied, is correctly secured in the holder.
The o en chamber is at ambient temperature, i.e. below 30 °C (86 °F).
Brakes are applied on the swi el castors.
O en and cold side fans are stopped.
9. Correct Use
The No aflex II has been designed for the following uses:
Regeneration of plated, chilled meals from +3°C to +75°C (+37°F to +162°F).(*)
Meal ser ice of hot and cold foods. (**)
Holding of cold plated meals prior to Regeneration.(***)
(*) ersions with double fridge, single fridge or without refrigeration
(**) ersions with double fridge or single fridge only
(***) ersion with double fridge and single fridge only. Single fridge can hold only on cold side while hot side is
only for rethermalization.
It is not recommended that the trolley be used for any other purpose than described abo e.
10. Working Environment
In order to guarantee the correct and safe functioning of your Burlodge trolley, it should be used in a clean, dry
en ironment the compressor is tropically rated at 43 degrees with temperatures the working ambient range is
between +10°C but the maximum ambient temperature should ne er exceed 30°C (86°F) ISO 15502 . Maximum
relati e humidity does not exceed alue of 65%.
Failure to comply will in alidate the warranty and may reduce the life span of certain components of your trolley
Your Burlodge trolley is designed for indoor use only and must be protected from external weather conditions at
all times.
11. Trolley isposal
It is the responsibility of the user to ensure that local laws and regulations are complied with when dismantling the
trolley and disposal of all packaging and freight materials.
Ensure that all door locking mechanisms are remo ed before to dispose the trolley.