Smartphone App for Air and Gas Flow Meter

Dear Customer,
Thank you for choosing our product.
Please read the manual in full before you start up the device and
carefully observe the instructions stated. The manufacturer cannot be
held liable for any damage which occurs as a result of non-observance
or non-compliance with this manual.
hould the device be tampered with in any manner other than a
procedure which is described and specified in the manual, the warranty
is void and the manufacturer is exempt from liability.
The device is destined exclusively for the described application.
UTO offers no guarantee for the suitability for any other purpose.
UTO is also not liable for consequential damage resulting from the
delivery, capability or use of this device.
2 S4C-FS

Table of contents
1 Registered trademarks.................................................................4
2 Application.................................................................................5
2.1 ystem requirements.............................................................5
2.2 Operating requirements.........................................................5
3 Features....................................................................................6
4 Installation and connection...........................................................6
4.1 Installation...........................................................................6
4.2 Enable the configuration.........................................................7
4.2.1 can QR code..............................................................7
4.2.2 Register for configuring 431.........................................8
5 Menus.......................................................................................9
5.1 Online................................................................................10
5.2 ettings.............................................................................10
5.3 ystem..............................................................................11
6 ettings...................................................................................11
6.1 Flow settings.......................................................................11
6.2 Gas type............................................................................12
6.3 Units settings......................................................................12
6.3.1 Flow units..................................................................13
6.3.2 Pressure units............................................................13
6.3.3 Temperature units.......................................................13
6.3.4 Consumption units......................................................14
6.4 Reference conditions............................................................14
6.5 Factory settings...................................................................14
6.6 Counter settings..................................................................15
6.7 Output settings...................................................................15
6.8 Calibration..........................................................................17
6.8.1 Calibration type..........................................................17
6.8.2 Calibration parameters................................................17
6.9 Logger settings...................................................................18
6.10 Upload settings.................................................................18
6.11 Download settings.............................................................18
7 ystem....................................................................................19
7.1 ensor information..............................................................19
7.2 Language...........................................................................19
7.3 App version........................................................................19
8 Maintenance.............................................................................20
S4C-FS 3

2 Application
2 Application
The 4C-F is an app that enables you to view measurement readings
and change settings for UTO flow meters through Android or iO
devices.
The 4C-F supports the following UTO flow meters:
•401, 402 and 421
•415 and 418
•418-V
•430
•431
2.1 System requirements
Ensure that your Android or iO devices meet the following
requirements:
•Android 7.0 or above versions installed
•iO 13 or above versions installed
•BLE4.0 and above supported (You can check the information with
the device vendor.)
Ensure that you have allowed the app to access the following
information:
•Location (Network-based approximate location and GP - and
Network-based precise location)
•Camera ( can the QR code)
•Pair with Bluetooth devices
•Device ID and call information (Read phone status and identity)
•Others (View network connections, View Wi-Fi connections, Access
Bluetooth settings, Change network connectivity, full network
access)
2.2 Operating requirements
The 4C-F can automatically detect a UTO flow meter when both of
the following requirements are satisfied:
•The UTO flow meter is powered on.
S4C-FS 5

2 Application
•The device is no more than 10-meter away from the flow meter
(within sight). Walls and metal enclosures will reduce the effective
distance!
3 Features
•mart phones and tablets applicable.
•Designed for service people to check sensor readings and change
sensor settings using Android or iO devices.
•Bluetooth integrated as the interface to communicate with the flow
meter.
•Multiple languages supported: English, German, Chinese, and
French.
4 Installation and connection
4.1 Installation
The Android-based 4C-F App file (*.APK) is available for download on
Google Play tore (play.google.com) and the UTO Website. (www.suto-
itec.com). The iO -based 4C-F App can be downloaded from Apple
App tore.
Use your mobile phone or tablet to download and install the application,
same as you do for any other apps.
After the 4C-F is launched on a device, the 4C-F automatically
detects powered-on flow meters within the valid distance of the device's
bluetooth signal.
When the 4C-F detects a flow meter for the first time, the 4C-F
has the Read-only access to the flow meter and can only view readings
and settings.
As shown in the following figure, a flow meter is detected with its name
and serial number displayed. The signal icon is shown in ED indicating
that the flow meter is Read-only. By clicking the flow meter name, you
trigger the 4C-F to connect with the flow meter. After the connection
is built, you are directed to the online view of the flow meter where you
can view the measurement data.
6 S4C-FS

4 Installation and connection
Note: The 4C-F can detect and connect to multiple flow meters. A
flow meter can connect to only one Android or iO device at a time.
4.2 Enable the configuration
Before using the 4C-F App to configure or calibrate flow meters, you
must obtain configuration permissions.
•For 401, 402, 421, 415, 418, 418-V, and 430, you can
scan the QR code of a specific flow meter to obtain its
configuration permission.
•For 431, you must register to obtain the configuration
permission.
4.2.1 Scan Q code
This function is applicable to flow meters supported by the 4C-F
except the 431.
To change settings of a flow meter, you must scan its QR code using the
4C-F App.
Preparation:
•Power on the flow meter.
•Obtain the QR code of the flow meter. The QR code is attached on
the side of the flow meter head or on the calibration certificate.
Following is an example of the QR code.
Steps:
1. Launch the S4C-FS on your phone.
The flow meters that are within the reach of the device's Bluetooth
S4C-FS 7

4 Installation and connection
are displayed on the screen, followed by a red signal icon.
2. Click the Scan Q Code button.
3. can the QR code on the flow meter's head or certificate.
After scanning the QR code, 4C-F saves the sensor information
to the Android or iO device, and the signal icon changes from
ED to G EEN, indicating that the flow meter is configurable
using the 4C-F .
Note: A G EEN hollow signal icon as shown in the following
figure indicates that the Bluetooth signal is weak. You can place
your device closer to the flow meter.
4.2.2 egister for configuring S431
This function is only applicable to the 431.
Before using the 4C-F App to configure or calibrate the 431, you
must register. Only registered users are able to modify settings. Please
get in touch with UTO service teams and provide the required
registration information.
8 S4C-FS

5 Menus
5.1 Online
The Online menu enables you to view the online measurement values
which are updated twice per second. Different flow meters have slightly
different measurement parameters as shown in the following table.
Flow meter Measurement
401 Flow, Consumption, Consumption[R]
402 Flow, Consumption, Consumption[R]
421 Flow, Consumption
430 Flow, Consumption, Consumption[R], Temperature, Velocity, Pressure
415 Flow, Consumption
418 Flow, Consumption, Pressure
418-V Flow, Consumption, Pressure
431 Flow, Consumption, Temperature, Velocity, Pressure
emarks:
The 418 shows the pressure only if the optional pressure sensor is
integrated.
5.2 Settings
The ettings menu enables you to change sensor settings and calibrate a
sensor. The ettings menu is enabled only when the 4C-F is completed
with scanning the QR code of the flow meter.
UTO flow meters provide various settings which influence the
performance and the features of the flow meters. Be careful when you
change the settings because they might affect the accuracy or the
overall performance. Contact UTO service team for information.
The following settings are available on UTO flow meters:
•Flow ettings
•Gas Type
•Units ettings
•Reference Conditions
•Factory ettings
•Counter ettings
•Output ettings