Aven Mighty Scope 1.3M Bedienungsanleitung

Mighty Scope 1.3M
Instruction Manual

1
Features 2
Specifications 2
Contents 2
PC System Requirements 3
Driver Installation Procedure 3
Getting Started 3
Software Installation (PC) 4
Mighty Scope Controls 6
MacroViewer Software 8
Function Key Lists 9
Compare 10
Video Setup 12
Preview picture mode 13
Measuring 14
Software Installation (Mac) 22
MacroViewer Software (Mac) 23
Function Key Lists 24
Compare 25
Video Setup 26
Measuring 27
Draw (Mac) 35
FAQ 36
Contents

2
Mighty Scope 1.3M Instruction Manual
DIGITAL MIGHTY SCOPE 1.3M
IMAGE SENSOR 1/4” Color CMOS
EFFECTIVE PIXELS 1.3M
SIGNAL OUTPUT USB 2.0
FRAMES PER SECOND: 640 x 480: 30fps
1280 x 1024 : 15fps
OPTICAL MAGNIFICATION Resolution: 640 x 480 | Max.~85X
Resolution: 1280 x 1024 | Max.~175X
DIGITAL MAGNIFICATION Optical Magnification *max. 6X
GAIN CONTROL Auto Gain Control
SNAP SHOT MODE Hardware & Software controllable
WHITE BALANCE Automatic
POWER SOURCE 5VDC through USB port
O/S Windows XP SP3, Vista & 7
Mac OSX 10.6
POWER CONSUMPTION 260mA (AVG)
LED LIGHT TYPE 6 White LEDs
WORKING DISTANCE At 10x, 112mm | At 20x, 42mm
At 30x, 19mm | At 40x, 8.5mm
The Mighty Scope digital microscope provides a
adjustable magnification range, and the 500X model
provides 500X(fixed) magnification. The built-in brightness
adjustable LEDs provides proper illumination of the object.
The magnified image can be viewed, captured and
recorded directly from the computer screen.
Science Engineering
Work Dermatology
Detailed Repair
Assembly
Quality Control
Hobbies
Law Enforcement
Entertainment
& much more
Mighty Scope (1)
MicroViewer Software CD (1)
User manual (1)
Stand (1)
Features Applications
Contents
Specifications

3
• Chip set: Pentium 4 2.4GHz CPU or equivalent,
AMD Phenom II or above, Northbridge Intel®
i945GZ or above
• RAM: 512MB DDR or above
• USB: At least one USB 2.0
•Graphics Card: 2D/3D with Hardware Transform
and lighting, 64MB VRAM VGA system and at least
16 bit color support
• Monitor Resolution: 1280x1024 or above
• O/S: Windows XP SP3 | VISTA | Windows 7
• Direct X 9.0c or above
PC System Requirements
• Chip set: Intel®Core™ 2 Duo or above /
Intel G31 or above
•Graphics Card: NVIDIA®GeForce® 7 or above
• RAM: 1024 DDR2 800MHz or above
• Storage space: at least 30MB free space
PC System Requirements (Dual Scope)
• Chip set: Intel®Processor
• O/S: Mac OS X 10.6 or later
Mac System Requirements
This device supports “Universal Video Class” driver, so
no additional driver is required. Plug the camera in and
Windows (Windows XP SP3, VISTA, and 7) will install
the driver automatically.
Driver Installation
Stand Assembly
Screw together vertical
pole and base
Assemble the scope’s
2-piece rack and pinion
holder and tighten screw
Getting Started

4
Mighty Scope 1.3M Instruction Manual
1. Insert the software
installation CD into
the CD-ROM drive.
The installation
program will appear
automatically on
your screen. (If the
installation program doesn’t appear, open the
MicroViewer folder and double click AutoRun.exe)
2. Click “Install MicroViewer 1.3MP” button (Fig.1).
Software Installation (PC)
Connect the scope holder
to the vertical post and
tighten set-screw
Place the Mighty Scope is
the holder and adjust to
desired working distance
**The Mighty Scope must be plugged
into the computer to open and run the
MicroViewer software. The MicroViewer will
not run without a Mighty Scope connected.
FIG. 1

5
3. Install the MicroViewer 1.3MP program
and restart the computer.
Software Installation (PC) cont.
1.3MP 1.3MP
1.3MP 1.3MP
1.3MP
1.3MP
1.3MP

6
Mighty Scope 1.3M Instruction Manual
4. Connect the Might Scope to the computer (Fig. 2).
5. Double Click the [MicroViewer 1.3MP]software,
the start-up screen will show up (Fig. 3).
6. Place the camera on or above the object to be
viewed (Fig. 4).
7. Tilt the digital microscope slightly when viewing
the object in order to get more depth of field to
resemble a 3D image (Fig. 5).
8. The Mighty Scope can be used to get the desired
magnification preferred by the user. The closer the
Mighty Scope is to the object, the larger image will
be and higher magnification (Fig. 6).
9. A clear focused image is obtained by adjusting
the focus knob as well as changing the distance
between the object and the Mighty Scope (Fig. 7).
10. If the image is blurred, adjust the focus knob to the
right end and view the image of the object in lower
magnification first (Fig. 8).
FIG. 3
FIG. 4
FIG. 5
FIG. 6 FIG. 7 FIG. 8
Mighty Scope Controls
FIG. 2

7
11. When magnifying an object, adjust the focus
knob slightly to the left or right, depending on the
working distance, until image is clear (Fig. 9).
12. If the object has too much relief or if a higher
magnification is unnecessary, lift the Mighty Scope
a little bit and adjust the focus knob slightly to the
right or left until the image is clear (Fig. 10).
13. LEDs can be adjusted by the light wheel. Turn the
knob to the right to get a brighter light and to the
left to get a dimmer light (Fig. 11).
14. When using high magnification to observe a
specific area of the object, placing the digital
microscope on the stand holder is recommended to
obtain a clearly focused image (Fig. 12).
15. Use snapshot button to capture an image (Fig. 13).
FIG. 9
FIG. 10
FIG. 11
FIG. 12
FIG. 13
Mighty Scope Controls

8
Mighty Scope 1.3M Instruction Manual
1. Double click the [MicroViewer 1.3]icon on your
desktop (Fig. 14).
• Make sure the Mighty Scope is plugged into the
USB port.
• Key in the Serial Number (which can be found on
the outside of the CD envelope) or just press the
“Evaluate” button for a 30 day free trial (Fig. 15).
• ”TV Card Configuration” window will show up the
first time, click the “OK” button and double click the
MicroViewer 1.3MP again (Fig. 16).
2. The MicroViewer 1.3MP window will show up and you
should see the live image from the Microscope (Fig. 17).
**The MicroViewer 1.3 will choose the appropriate video format
automatically by detecting the resolution of the monitor. If the
resolution is 1280x1024 (or above), the default video format is
1024x768. If the resolution is 1024x768(or below), the default
video format is 640x480.
MicroViewer Software
Function Key
Live zone
List bar
FIG. 14
FIG. 15
FIG. 16
FIG. 17
Inhaltsverzeichnis
Andere Aven Mikroskop Handbücher
Beliebte Mikroskop Handbücher anderer Marken

Thermo Scientific
Thermo Scientific Nicolet iN10 Leitfaden

National
National DC3-163 Bedienungsanleitung

KERN Optics
KERN Optics OPE-1 Bedienungsanleitung

OPTIKA MICROSCOPES
OPTIKA MICROSCOPES B-150D Bedienungsanleitung

Prior
Prior Lux POL Bedienungsanleitung

Opitec
Opitec Smartscoop 115615 Bedienungsanleitung

VWR
VWR VisiScope 384 Series Bedienungsanleitung

Nikon
Nikon ECLIPSE E200 POL Bedienungsanleitung

Leica
Leica DI C800 Handbuch

ThermoFisher Scientific
ThermoFisher Scientific Continuµm Bedienungsanleitung

ThermoFisher Scientific
ThermoFisher Scientific Continuµm Bedienungsanleitung

Olympus
Olympus SZ61 Bedienungsanleitung