* When converted using Kit 0591149.
The appliance data label is located on a plate at the base of the fire. This can be seen by
removing the lower firefront and casting.
3. GENERAL INSTALLATION REQUIREMENTS
3.1 The installation must be in accordance with these instructions.
For the user’s protection, in the United Kingdom it is the law that all gas appliances are
installed by competent persons in accordance with the current edition of the Gas Safety
(Installation and Use) Regulations. Failure to install the appliance correctly could lead
to prosecution. The Council for the Registration of Gas Installers (CORGI) requires its
members to work to recognised standards.
In the United Kingdom, all electrical supply installation must be installed in accordance
with the current edition of the IEE Wiring Regulations (BS7671).
In the United Kingdom the installation must also be in accordance with:
a) All the relevant parts of local regulations.
b) The current edition of the Building Regulations issued by the Department of the
Environment and the Welsh Office or the Building Standards (Scotland) (Consolidation)
Regulations issued by the Scottish Development Department.
Page 5
INSTALLER GUIDE
Gas Natural (G20) Propane (G31) *
Inlet Pressure 20mbar 37mbar
Input - Max. (Gross) 6.0kW (20,500Btu/h) 6.1kW (20,800Btu/h)
Input - Min. (Gross) 2.2kW (7,500Btu/h) 3.6kW (12,280Btu/h)
Output - Max. 3.12kW (10,600Btu/h)
Output - Min 1.1kW (3,750Btu/h) 1.8kW (6,140Btu/h)
Inlet Test Pressure (Cold) 14.9 ± .75mbar (6.0 ± 0.3in
w.g.)
0.3in w.g.)
Gas Connection 8mm pipe 8mm pipe
Burner Injector Bray Cat. 18 Size 400 Bray Cat. 18 Size 170
Pilot & Atmosphere Sensing
Device SIT Ref. NGOP9044 SIT Ref. OPLPG9222
Ignition Piezo Electric. Integral with
Gas Tap
Piezo Electric. Integral with
Gas Tap
Aeration Non-adjustable Non-adjustable
Electrical Supply 230V ~ 50Hz AC 230V ~ 50 Hz AC
Fan motor rating 55W 55W
Fuse rating 3A 3A