Terreon Multi-Fount Washfountains Parts and Service
43/11/2014 Bradley•215-1447 Rev. H; ECN 14-00-003
Infrared (IR) Valve Assembly - Solenoid Valve S07-068S (Closed
Body) and S07-068AS (Thru Body)
1
2
11
3
4
5
6
7
8
9
8
10
Item Part No. Description Qty
1 118-307 Valve Body, 1/4" Closed 1
1 118-307A Valve Body, 1/4", Through 1
2 269-983 Diaphragm 1
3 269-577 Armature 1
4 269-578 Spring 1
5 269-1729 Armature Housing 1
6 269-1730 clamp, Armature Housing 1
7 269-579 Coil, Solenoid Valve 1
8 160-447 Screw #8 x 5/8 3
9 125-165 O-Ring, #2-013 1
10 125-160 Flow Restrictor, 0.5 GPM 1
11 S65-113 Repair Kit 1
Solenoid Valve Parts List
Turn off water supplies to unit before troubleshooting.
Problem Cause Solution
An individual
operating station
fails to shut off and
drips.
There is debris
trapped between
the diaphragm and
the valve seat.
Remove debris between diaphragm and the valve seat.
1. Remove the three #8 Phillips-head screws that hold the solenoid valve assembly together. Be
careful not to lose the armature or spring (see previous page).
2. Remove the diaphragm. Remove any particles that have been trapped between the diaphragm
and the valve seat. Rinse off the diaphragm and inspect for damage. Make sure the center orifice
and both small side orifices are open.
3. Reassemble in reverse order, being careful not to overtighten the Phillips-head screws or you
may crack the plastic valve body. Tighten until the armature plate makes contact with the plastic
body.
4. Reconnect the wiring per diagram.
An individual
operating station
fails to turn on.
A failed coil for
the valve or
loose electrical
connection to the
terminal.
Test the station to determine cause.
1. Disconnect the wires from the coil of an adjacent valve. Disconnect the wires from the problem
valve and reconnect to the adjacent valve.
2. Turn on electrical and water supplies to the unit. Place hands in front of sensor for the problem
station; the adjacent station should turn on.
If the adjacent station turns on and cycles normally, replace the coil on the problem valve.
If the adjacent valve fails to turn on, inspect the wires from the sensor cable and do the following:
•makesuretherearenobreaksandthatthefullyinsulateddisconnectterminalsarefirmlycrimped in place;
•turnofftheelectricalandwatersupplies;•reconnecttotheadjacentvalveandturnonthewatersuppliestotheunit;•placehandsinfrontofsensor.Ifthestationstillfailstoturnon,replacethesensor.