INSTALLATION
1. Identify all components and check for completeness, particularly before
arranging installation.
2. Fit the legs to the body using the large sealing washers.
3. Fit the mixer to the bath using the backnuts and washers, connect the hot and cold
water supplies.
4. Fit the cradle to the mixer (if not already fitted), using the large sealing washer.
5. Fit the hose to the cradle and the handset using the small sealing washers.
6. Fully open both valves, letting them run for a few minutes to flush the system.
7. Operate the mixer in both bath and shower mode. To switch from bath to shower
mode, move the diverter lever from one extreme to the other.
8. Check all joints and connections for leaks.
9. See over the page for aftercare instructions.
N.B. Please write the name and product code of your fitting in the spaces
provided overleaf. This will ensure a speedier service if you should need to
phone the help line.
MAINTENANCE
Sureflow type valves: - If the fitting self-opens
1. Remove fitting head.
2. Tighten gland nut on top of valve.
Traditional type valves: - If the fitting leaks from the spindle
1. Remove fitting head (if necessary).
2. Tighten gland nut on top of valve.
All valve types: - If the fitting begins to drip
1. Turn off the water supply.
2. Remove fitting head and valve.
3. Carefully clean seating and rubber washer.
4. Replace valve and turn on the water supply.
5. Contact our helpline if problem persists.
Before starting any installation project please consider:
Prior to drilling into walls, check there are no hidden electrical
wires, cables or water supply pipes with the aid of an electronic
detector. If you use power tools do not forget:
- Wear eye protection
- Unplug equipment after use
SAFETY
NOTE
10
5
6
4
2
3
1
7
21
20
19
25
7
11
12
13
14
15
16
17
18
WATER PRESSURE
This mixer is suitable for use at all supply pressures. However, for optimum use, both
the hot and cold supplies should be reasonably balanced.
If the fitting is installed at low pressure (tank fed), then the minimum distance from
the highest installed position of the shower head to the underside of the cold tank
should be 2 meters to ensure adequate shower performance.
This mixer should be installed in compliance with the Water Regulations. Where the
supplies are unbalanced, i.e. hot water from cylinder tank/cold from the mains, approved
check valves must be fitted in the supply pipes.
CONTENTS
HANDSET & HOSE KIT (1-2)
WALL HOOK KIT (3)
HANDSET DIVERTER
KIT (4-9)
VALVE BODY (10)
DIVERTER HANDLE
AND KIT (11-14)
CARTRIDGE (15)
HANDLE & INDICE KIT (16-18)
SPOUT (19)
AERATOR KIT (20-21)
INLET LEG KIT (22-27)
VAC PBSM C MT
VAC PBSM C NH (NO HEAD)(Supplied with no
handles fitted. Handles purchased separately).