9
English
Test Data
Commission Regulation (EC) No 1275/2008 Requirement
Mode Ecodesign requirements, from 7 January 2013 Result - Remark Verdict
Off mode Power consumption in ‘off mode’:
Power consumption of equipment in any off-mode
condition shall not exceed 0.50 W
0.00 W P
Standby mode Power consumption in ‘standby mode(s)’:
Thepower consumption of equipment in any
condition providing only areactivation function,
or providing only areactivation function and
amere indication of enabled reactivation fun-
ction, shall not exceed 0.50 W.
N/A
Thepower consumption of equipment in any
condition providing only information or status
display, or providing only acombination of reacti-
vation function and information or status display
shall not exceed 1.00 W.
N/A
Seasonal space heating energy efficiency
Description Value
Seasonal space heating energy efficiency in active mode-ηS,on 40 %
For electric local space heaters-ηth
Theelectric to primary energy “conversion coefficient”-CC
F(1) is acorrection factor accounting for apositive contribution to theseasonal space
heating energy efficiency of electric storage local space heaters due to adjusted
contributions for options for heat storage and output; and anegative contribution
to seasonal space heating efficiency for commercial local space heaters due to
adjusted contributions for options for theheat output, expressed in %;
0.0 %
F(2) is acorrection factor accounting for apositive contribution to theseasonal
space heating energy efficiency due to adjusted contributions of controls of indoor
heating comfort, thevalues of which are mutually exclusive, cannot be added to
each other, expressed in %;
6.0 %
F(3) is acorrection factor accounting for apositive contribution to theseasonal
space heating energy efficiency due to adjusted contributions of controls for indoor
heating comfort thevalues of which can be added to each other, expressed in %;
0.0 %
F(4) is acorrection factor accounting for anegative contribution to theseasonal
space heating energy efficiency by auxiliary electricity consumption, expressed in %; 0.0 %
F(5) is acorrection factor accounting for anegative contribution to theseasonal
space heating energy efficiency by energy consumption of apermanent pilot flame,
expressed in %.
0.0 %
Seasonal space heating energy efficiency-ηS36.00 %
Verdict P