MR MSENSE DGA 2/3 Bedienungsanleitung

Online oil analysis
MSENSE® DGA 2/3
Operating instructions
4001150/12 EN

© All rights reserved by Maschinenfabrik Reinhausen
Dissemination and reproduction of this document and use and disclosure of its content are strictly prohibited
unless expressly permitted.
Infringements will result in liability for compensation. All rights reserved in the event of the granting of patents,
utility models or designs.
The product may have been altered since this document was published.
We reserve the right to change the technical data, design and scope of supply.
Generally the information provided and agreements made when processing the individual quotations and orders
are binding.
The original operating instructions were written in German.

Table of contents
Maschinenfabrik Reinhausen GmbH 2023 34001150/12 EN MSENSE® DGA 2/3
Table of contents
1 Introduction......................................................................................................................... 6
1.1 Manufacturer....................................................................................................................................... 6
1.2 Subject to change without notice ........................................................................................................ 6
1.3 Completeness..................................................................................................................................... 6
1.4 Safekeeping........................................................................................................................................ 6
1.5 Notation conventions .......................................................................................................................... 6
1.5.1 Hazard communication system .............................................................................................................................7
1.5.2 Information system................................................................................................................................................7
1.5.3 Instruction system .................................................................................................................................................8
1.5.4 Typographic conventions ......................................................................................................................................8
2 Security ............................................................................................................................... 9
2.1 Intended use ....................................................................................................................................... 9
2.2 Fundamental safety instructions ......................................................................................................... 9
2.3 Personnel qualification...................................................................................................................... 11
2.4 Personal protective equipment ......................................................................................................... 12
3 IT security.......................................................................................................................... 14
4 Product description.......................................................................................................... 15
4.1 Scope of delivery .............................................................................................................................. 16
4.2 Function description.......................................................................................................................... 17
4.3 Design/versions ................................................................................................................................ 18
4.4 Safety markings and nameplate ....................................................................................................... 19
5 Packaging, transport and storage .................................................................................. 20
5.1 Purpose ............................................................................................................................................ 20
5.2 Suitability, structure and production.................................................................................................. 20
5.3 Markings ........................................................................................................................................... 20
5.4 Transportation, receipt and handling of shipments........................................................................... 20
5.5 Storage of shipments........................................................................................................................ 22
5.6 Further transport ............................................................................................................................... 22
6 Mounting ........................................................................................................................... 23
6.1 Installation recommendation............................................................................................................. 23

Table of contents
Maschinenfabrik Reinhausen GmbH 202344001150/12 ENMSENSE® DGA 2/3
6.2 Mounting the device.......................................................................................................................... 24
6.2.1 Preparing the transformer and ball valve ............................................................................................................25
6.2.2 Mounting the MSENSE® DGA 2/3......................................................................................................................29
6.3 Electrical connection......................................................................................................................... 38
6.3.1 Electromagnetic compatibility..............................................................................................................................39
6.3.2 Cable recommendation .......................................................................................................................................39
6.3.3 Routing and preparing the cables .......................................................................................................................39
6.3.4 Supply voltage and protective conductor ............................................................................................................40
6.3.5 Device grounding ................................................................................................................................................41
6.3.6 Analog outputs ....................................................................................................................................................41
6.3.7 Main switching contacts ......................................................................................................................................43
6.3.8 SCADA connection .............................................................................................................................................44
6.4 Ensuring offshore capability.............................................................................................................. 47
7 Commissioning................................................................................................................. 50
7.1 Service interface ............................................................................................................................... 50
7.2 Installing the MESSKO® MSET parameterization software ............................................................. 51
7.3 Commissioning in existing systems .................................................................................................. 52
7.4 Parameterization............................................................................................................................... 52
7.4.1 Settings for carbon monoxide (DGA 3 only), hydrogen and H2O concentrations in the oil ................................53
7.4.2 General settings ..................................................................................................................................................54
7.4.3 Modbus settings ..................................................................................................................................................56
8 Operation........................................................................................................................... 57
8.1 Operating the device with display ..................................................................................................... 58
8.1.1 General operation ...............................................................................................................................................59
8.1.2 Main screen / operating display ..........................................................................................................................60
8.1.3 Events .................................................................................................................................................................62
8.2 Operating the device without display ................................................................................................ 64
9 Fault elimination ............................................................................................................... 65
9.1 Messages regarding the safety switching contact ............................................................................ 65
9.2 Display faults .................................................................................................................................... 65
9.3 Replacing a fuse ............................................................................................................................... 65
10 Maintenance...................................................................................................................... 67
10.1 Inspection ......................................................................................................................................... 67
10.2 Maintenance ..................................................................................................................................... 68

Table of contents
Maschinenfabrik Reinhausen GmbH 2023 54001150/12 EN MSENSE® DGA 2/3
10.3 Oil extraction..................................................................................................................................... 69
10.4 Device field calibration...................................................................................................................... 70
10.4.1 Taking a sample for field calibration....................................................................................................................70
10.4.2 Field calibration ...................................................................................................................................................72
10.4.3 Reading out the service database.......................................................................................................................78
10.5 Cleaning............................................................................................................................................ 80
11 Removal............................................................................................................................. 81
11.1 Removing the MSENSE® DGA 2/3.................................................................................................. 81
12 Disposal............................................................................................................................. 89
12.1 SVHC information in accordance with the REACH regulation.......................................................... 89
13 Technical data................................................................................................................... 90
14 Appendix ........................................................................................................................... 93
14.1 Device dimensions with 285mm measuring pipe length.................................................................. 93
14.2 Device dimensions with 507mm measuring pipe length.................................................................. 94
14.3 Connecting flange dimensions.......................................................................................................... 95
14.4 Electrical connection......................................................................................................................... 97
14.5 Data point table for Modbus RTU ..................................................................................................... 98
14.6 Spare parts list................................................................................................................................ 100
Glossary .......................................................................................................................... 102

1 Introduction
Maschinenfabrik Reinhausen GmbH 202364001150/12 ENMSENSE® DGA 2/3
1 Introduction
This technical file contains detailed descriptions on the safe and proper in-
stallation, connection, commissioning and monitoring of the product.
This technical document is intended solely for specially trained and autho-
rized personnel.
1.1 Manufacturer
Maschinenfabrik Reinhausen GmbH
Falkensteinstrasse 8
93059 Regensburg
Germany
Tel.: +49 941 4090-0
E-mail: [email protected]
Internet: www.reinhausen.com
MR Reinhausen customer portal: https://portal.reinhausen.com
Further information on the product and copies of this technical file are avail-
able from this address if required.
1.2 Subject to change without notice
The information contained in this technical file comprises the technical speci-
fications approved at the time of printing. Significant modifications will be in-
cluded in a new edition of the technical file.
The document number and version number of this technical file are shown in
the footer.
1.3 Completeness
This technical file is incomplete without the supporting documents.
The following documents apply to this product:
▪ MSENSE®DGA 2/3 operating instructions
▪ MESSKO®MSET parameterization software operating instructions
▪ Works certification
1.4 Safekeeping
Keep this technical file and all supporting documents ready at hand and ac-
cessible for future use at all times.
1.5 Notation conventions
This section contains an overview of the symbols and textual emphasis
used.

1 Introduction
Maschinenfabrik Reinhausen GmbH 2023 74001150/12 EN MSENSE® DGA 2/3
1.5.1 Hazard communication system
Warnings in this technical file are displayed as follows.
1.5.1.1 Warning relating to section
Warnings relating to sections refer to entire chapters or sections, sub-sec-
tions or several paragraphs within this technical document. Warnings relat-
ing to sections have the following format:
WARNING Type of danger!
Source of the danger and its consequences.
► Action
► Action
1.5.1.2 Embedded warning information
Embedded warnings refer to a particular part within a section. These warn-
ings apply to smaller units of information than the warnings relating to sec-
tions. Embedded warnings use the following format:
DANGER! Instruction for avoiding a dangerous situation.
1.5.1.3 Signal words
Depending on the product, the following signal words are used:
Signal word Meaning
DANGER Indicates a hazardous situation which, if not avoided, will result in
death or serious injury.
WARNING Indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
CAUTION Indicates a hazardous situation which, if not avoided, could result
in minor or moderate injury.
NOTICE Indicates measures to be taken to prevent damage to property.
Table1: Signal words in warning notices
1.5.2 Information system
Information is designed to simplify and improve understanding of particular
procedures. In this technical file it is laid out as follows:
Important information.

1 Introduction
Maschinenfabrik Reinhausen GmbH 202384001150/12 ENMSENSE® DGA 2/3
1.5.3 Instruction system
This technical file contains single-step and multi-step instructions.
Single-step instructions
Instructions which consist of only a single process step are structured as fol-
lows:
Aim of action
üRequirements (optional).
► Step 1 of 1.
ðResult of step (optional).
ðResult of action (optional).
Multi-step instructions
Instructions which consist of several process steps are structured as follows:
Aim of action
üRequirements (optional).
1. Step 1.
ðResult of step (optional).
2. Step 2.
ðResult of step (optional).
ðResult of action (optional).
1.5.4 Typographic conventions
Typographic convention Purpose Example
UPPERCASE Operating controls, switches ON/OFF
[Brackets] PC keyboard [Ctrl] + [Alt]
Bold Software operating controls Press Continue button
…>…>… Menu paths Parameter > Control parameter
Italics System messages, error messages,
signals
Function monitoring alarm triggered
[► Number of pages] Cross reference [► Page41].
Dotted underscore
.............................................
Glossary entry, abbreviations, defini-
tions, etc.
Glossary entry
........................
Table2: Typographic conventions used in this technical file

2 Security
Maschinenfabrik Reinhausen GmbH 2023 94001150/12 EN MSENSE® DGA 2/3
2 Security
▪ Read this technical file through carefully to familiarize yourself with the
product.
▪ This technical file is a part of the product.
▪ Read and observe the safety instructions provided in this chapter in partic-
ular.
▪ Observe the warnings in this technical file to avoid function-related dan-
gers.
▪ The product is manufactured based on state-of-the-art technology. Never-
theless, danger to life and limb for the user or impairment of the product
and other material assets may arise in the event of improper use.
2.1 Intended use
The product is designed solely for use in stationary large-scale systems.
It is designed to detect and report emerging, potentially harmful trends in the
monitored equipment (e.g. transformer) in good time by measuring the con-
centration of gases and moisture in the equipment's insulating oil.
The device is not designed and is not suitable for detecting rapidly develop-
ing faults and therefore is not intended to protect the equipment from such
faults (e.g. through shutdown). For this, please use safety devices that have
been designed for this purpose.
If used as intended and in compliance with the requirements and conditions
specified in this technical file as well as the warning notices in this technical
file and attached to the product, then the product does not present any dan-
ger to people, property or the environment. This applies throughout the ser-
vice life of the product, from delivery, installation and operation to removal
and disposal.
The following is considered intended use:
▪ Operate the product in accordance with this technical document, the
agreed-upon delivery conditions and the technical data.
▪ Ensure that all necessary work is performed by qualified personnel only.
▪ Only use the devices supplied for the intended purpose and in accordance
with the specifications in this technical document.
▪ Observe the notices in this technical document regarding electromagnetic
compatibility and the technical data.
2.2 Fundamental safety instructions
To prevent accidents, malfunctions and damage as well as unacceptable ad-
verse effects on the environment, those responsible for transport, installa-
tion, operation, maintenance and disposal of the product or parts of the prod-
uct must ensure the following:

2 Security
Maschinenfabrik Reinhausen GmbH 202310 4001150/12 ENMSENSE® DGA 2/3
Personal protective equipment
Loosely worn or unsuitable clothing increases the danger of becoming
trapped or caught up in rotating parts and the danger of getting caught on
protruding parts. This results in danger to life and limb.
▪ All necessary devices and personal protective equipment required for the
specific task, such as a hard hat, safety footwear, etc. must be worn. Ob-
serve the "Personal protective equipment" [►Section 2.4, Page 12] sec-
tion.
▪ Never wear damaged personal protective equipment.
▪ Never wear rings, necklaces or other jewelry.
▪ If you have long hair, wear a hairnet.
Work area
Untidy and poorly lit work areas can lead to accidents.
▪ Keep the work area clean and tidy.
▪ Make sure that the work area is well lit.
▪ Observe the applicable laws for accident prevention in the relevant coun-
try.
Explosion protection
Highly flammable or explosive gases, vapors and dusts can cause serious
explosions and fire.
▪ Do not install or operate the product in areas where a risk of explosion is
present.
Safety markings
Warning signs and safety information plates are safety markings on the
product. They are an important aspect of the safety concept. Safety mark-
ings are depicted and described in the chapter "Product description".
▪ Observe all safety markings on the product.
▪ Make sure all safety markings on the product remain intact and legible.
▪ Replace safety markings that are damaged or missing.
Ambient conditions
To ensure reliable and safe operation, the product must only be operated
under the ambient conditions specified in the technical data.
▪ Observe the specified operating conditions and requirements for the in-
stallation location.
Inhaltsverzeichnis
Andere MR Messgerät Handbücher

MR
MR MESSKO BeTech Bedienungsanleitung

MR
MR MESSKO MMK Bedienungsanleitung

MR
MR MSENSE BM Bedienungsanleitung

MR
MR MESSKO MFLOC 2.0 Bedienungsanleitung

MR
MR MSENSE DGA 9 Bedienungsanleitung

MR
MR MSENSE BM Bedienungsanleitung

MR
MR MSENSE DGA 2 Bedienungsanleitung

MR
MR MESSKO EI100 Bedienungsanleitung

MR
MR MESSKO MFLOC 2.0 Bedienungsanleitung

MR
MR MESSKO EI100 Bedienungsanleitung