Royce 610 Bedienungsanleitung

Royce Instruments
®
System 610 User Guide
ROYCE INSTRUMENTS, LLC.
831 Latour Court, Suite C
Napa, CA 94558
PH (707) 255-9078
FX (707) 255-9079
www.royceinstruments.com


Safety Precautions
•
Read and follow the instructions! All the safety and operating instructions must be read
before the machine is operated.
•
Use only the correct power source as marked on the machine - if you are not sure of the
power supply consult you local power company. If the machine uses a wall plug-in
transformer, use only the transformer supplied.
•
Your wall outlet must accept a polarized, three-prong grounded plug. These plugs are
designed for your safety, so do not attempt to defeat them. If you cannot insert the plug
easily, an electrician should replace the outlet.
•
Operators must be trained on the proper use of the machine and on handling pull hooks
before performing any tests.
•
Do not place hands or fingers at pinch points.
•
Do not use liquids where they can be spilled into the enclosure through openings.
•
Do not use machine if you suspect a gas leak. Report the leak immediately.
•
Do not use the machine near water, or when you are wet. If the machine comes in contact
with any liquids, unplug the power and line cords immediately.
Do not plug the machine back in until it has been dried thoroughly.
•
The machine must be serviced by qualified service personnel when:
o
The power supply cord or the plug has been damaged
o
Objects have fallen or liquid has been spilled into the machine
o
The machine has been exposed to rain
o
The machine does not appear to operate normally or exhibits a marked change in
the performance
o
The machine has been dropped, or the enclosure is damaged
•
Do not attempt to service the machine beyond the operating instructions.
All other servicing should be referred to qualified service personnel.
Opening the machine or reassembling it incorrectly may expose you to dangerous voltages
or other risks.
•
The Royce 610 system mainframe weighs 20 kg (45 lb.) with typical tooling installed.
Two people are needed to move or lift the system mainframe safely.

Copyright
This guide is copyrighted by Royce Instruments, LLC. with all rights reserved. Under U.S.
copyright laws, this manual may not be reproduced in any form, in whole or in part, without the
prior consent of Royce Instruments, LLC.
©2012 Royce Instruments, LLC.
Disclaimer
Royce Instruments, LLC. has reviewed this guide thoroughly. All statements, technical
information, and recommendations in this manual are believed reliable, but the accuracy and
completeness thereof are not guaranteed or warranted, and they are not intended to be, nor should
they be understood to be, representation or warranties concerning the products described.
Trademarks
Royce Instruments is a registered trademark of Royce Instruments, LLC.
Microsoft and Windows are registered trademarks of Microsoft Corporation. All other trademarks
mentioned in this guide are trademarks of their respective owners.
The information in this document is subject to change in order to improve reliability, design, or
function without prior notice and does not represent a commitment on the part of this company.

Get Help from Royce Instruments
Before you contact us, please record the following information.
System serial number : (located on the back of the machine)
––––––––––––––––––––––––––––––––––––––––––––––––
Installed software revision number : (displayed upon start up)
––––––––––––––––––––––––––––––––––––––––––––––––

Support Options
Internet – www.royceinstruments.com
Check us out online for answers to frequently asked questions and product information.
Email – customerservice@royceinstruments.com
For individual attention on a special issue, contact our knowledgeable technical support
representatives.
Process Consumables
Many consumable items are can be purchased directly from our website.
http://www.royceinstruments.com/consumables.html
Extended Warranty
Royce Instruments Extended Warranty is a cost-effective service and support program. For more
information, visit the Royce Instruments website.

TABLE OF CONTENTS
1. INTRODUCTION 1-1
2. GETTING STARTED 2-1
3. SETTING UP THE SYSTEM 3-1
4. OPERATING THE SYSTEM 4-1
5. READING TEST RESULTS 5-1
6. CALIBRATION 6-1
7. MENU STRUCTURE 7-1
8. TECHNICAL SPECIFICATIONS 8-1
9. LIMITED WARRANTY 9-1
10. PROBLEM REPORT FORM 10-1
11. INDEX 11-1

Declaration of Conformity
Déclaration de conformité
Konformitätserklärung
We, Royce Instruments, LLC.
Manufacturer, 831 Latour Ct, Suite C
Napa, California, 94558, USA
+1 (707) 255-9078
www.royceinstruments.com
Bearing sole responsibility,
hereby declare that the product: Wire pull-
test Bond Tester, Model 610
referred to by this declaration is in conformity
with the following standards or normative documents:
73/23/EEC Low Voltage Directive (LVD)
EN 61010-1:1993 Safety Requirements for Electrical Equipment +A2:1995
89/336/EEC Electromagnetic Compatibility (EMC)
EN 50081-2:1993 EMC, Part 2: Emission standard, Industrial environment
EN 50082-1:1992 EMC, Part 1: Immunity standard, Residential,
commercial and light industry
EN 55011:1991 Group 1 Class A Equipment, Limits of radio frequency

1-1
1. INTRODUCTION
1.1 MAINFRAME 1-2
1.2 OPTICS 1-3
1.3 WIRE PULL HOOKS 1-3
1.4 SAMPLE HOLDERS 1-4
1.6 OPTIONS 1-6

1-2
1.1 MAINFRAME
The System 610 mainframe includes illumination, mouse, LCD, parallel printer port, and
RS232 serial port. Standard features include pull hook rotation, conventional “semi auto”
test mode, and collision sensing. The System 610 wire pull tester is capable of 100 gram
testing force with a 0.1 gram resolution.
System 610 Mainframe
Inhaltsverzeichnis
Beliebte Mikroskop Handbücher anderer Marken

Thermo Scientific
Thermo Scientific Nicolet iN10 Leitfaden

National
National DC3-163 Bedienungsanleitung

KERN Optics
KERN Optics OPE-1 Bedienungsanleitung

OPTIKA MICROSCOPES
OPTIKA MICROSCOPES B-150D Bedienungsanleitung

Prior
Prior Lux POL Bedienungsanleitung

Opitec
Opitec Smartscoop 115615 Bedienungsanleitung

VWR
VWR VisiScope 384 Series Bedienungsanleitung

Nikon
Nikon ECLIPSE E200 POL Bedienungsanleitung

Leica
Leica DI C800 Handbuch

ThermoFisher Scientific
ThermoFisher Scientific Continuµm Bedienungsanleitung

ThermoFisher Scientific
ThermoFisher Scientific Continuµm Bedienungsanleitung

Olympus
Olympus SZ61 Bedienungsanleitung