TRISTAN TECHNOLOGIES SMM-770 Bedienungsanleitung

Scanning Magnetic
Microscope
Model SMM-770
Operating Guide
TRISTAN TECHNOLOGIES, Inc
San Diego, California
USA
www.tristantech.com

Model SMM 770 Scanning Magnetic Microscope System
TRISTAN TECHNOLOGIES --Page 2
Operating Guide
for
Single channel HTS SQUID microscope
Model SMM-770
Option 77P, 77V, 77T, 77B, 77HR, MS-770
TRISTAN TECHNOLOGIES, Inc
San Diego, California
USA
Copyright 2005
www.tristantech.com

Model SMM 770 Scanning Magnetic Microscope System
TRISTAN TECHNOLOGIES --Page 3
Revision Record
Date Revision Description
Ma
y
6
,
2005 Version 1. Initial Release
Ma
y
11, 2005 Version 1.1 actual data included
Ma
y
31, 2005 Version 1.2 more data
2005 by Tristan Technologies
All rights reserved. No part of this manual may be reproduced, stored in a retrieval
system, or transmitted in any form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, without prior written permission of
TRISTAN TECHNOLOGIES Inc.
TRISTAN TECHNOLOGIES Inc. reserves the right to change the functions, features,
or specifications of its products at any time, without notice.
Any questions or comments in regard to this product and other products from
Tristan Technologies, please contact or see http://www.tristantech.com:
Tristan Technologies
6191 Cornerstone Ct. East., Suite 107
San Diego, CA 92121
U. S. A.
Technical Support: (858) 550 – 2700
FAX: (858) 550 – 2799
info1@tristantech.com
http://www.tristantech.com

Model SMM 770 Scanning Magnetic Microscope System
TRISTAN TECHNOLOGIES --Page 4
WARRANTY
TRISTAN TECHNOLOGIES Limited Warranty
TRISTAN TECHNOLOGIES Inc. warrants this product for a period of twelve (12)
months from date of original shipment to the customer. Any part found to be
defective in material or workmanship during the warranty period will be repaired
or replaced without charge to the owner. Prior to returning the instrument for
repair, authorization must be obtained from TRISTAN TECHNOLOGIES Inc. or an
authorized TRISTAN TECHNOLOGIES service agent. All repairs will be warranted
for only the unexpired portion of the original warranty, plus the time between
receipt of the instrument at TRISTAN TECHNOLOGIES and its return to the owner.
This warranty is limited to TRISTAN TECHNOLOGIES’ products that are
purchased directly from TRISTAN TECHNOLOGIES, its OEM suppliers, or its
authorized sales representatives. It does not apply to damage caused by accident,
misuse, fire, flood or acts of God, or from failure to properly install, operate, or
maintain the product in accordance with the printed instructions provided.
This Warranty Is In Lieu Of Any Other Warranties, Expressed Or Implied,
Including Merchantability Or Fitness For Purpose, Which Are Expressly
Excluded. The Owner Agrees That TRISTAN TECHNOLOGIES’ Liability
With Respect To This Product Shall Be As Set Forth In This Warranty, and
Incidental Or Consequential Damages Are Expressly Excluded.

Model SMM 770 Scanning Magnetic Microscope System
TRISTAN TECHNOLOGIES --Page 5
Table of Contents
1. SYSTEM OVERVIEW 10
1.1 INITIAL INSPECTION 12
1.2 REPACKING FOR RETURN SHIPMENT 12
1.3 RETURN FROM CUSTOMERS OUTSIDE THE U.S.A. 12
1.4 SYSTEM COMPONENTS 12
2. CRYOGENIC SYSTEM 16
2.1 LIQUID NITROGEN MAINTENANCE 17
2.2 NORMAL INSTALLATION AND OPERATION 17
2.3 SAFETY PRECAUTIONS FOR HANDLING CRYOGENIC LIQUIDS 17
2.4 GENERAL INFORMATION 19
3. SENSORS AND CONTROL ELECTRONICS 20
3.1 WIRING DIAGRAM 20
3.2 SENSOR INITIAL PERFORMANCE TEST 22
3.3 MEASURED PARAMETERS AND FACTORY TEST DATA 22
3.4 SENSOR CALIBRATION 25
4. SYSTEM SOFTWARE 31
4.1 START 31
4.2 EXCITATION 33
4.3 TRACK CONSTRUCTION 33
4.4 MOVE MANUALLY 35
4.5 SQUID PARAMETERS 36
4.6 ACQUISITION PARAMETERS 37
4.7 FILTER PARAMETERS 38
4.8 SCAN CONTROLS 39
4.9 OUTPUT FILE 46
4.10 VIDEO CAMERA 50

Model SMM 770 Scanning Magnetic Microscope System
TRISTAN TECHNOLOGIES --Page 6
5. SERVICE AND MAINTENANCE 51
5.1 INSPECTION AND CLEANING 51
5.2 CRYOGENIC DEWAR MAINTENANCE 51
5.3 GANTRY MAINTENANCE 53
5.4 VIBRATION ISOLATION EQUIPMENT 53
6. OPTIONAL EQUIPMENT 53
6.1 OPTION 77P PNEUMATIC VIBRATION ISOLATION 53
6.2 OPTION 77V ACTIVE VIBRATION CANCELLATION 53
6.3 OPTION 77T TILT TIP FRAME 54
6.4 OPTION 77B FIXED FIELD CAPABILITY 55
6.5 OPTION 77HR 12.5 MICRON STEP CAPACITY 59
6.6 OPTION MS-770 TWO LAYER MU METAL MAGNETIC SHIELD 59
7. APPENDICES 62
7.1 THERMOMETRY AND COOLDOWN 62
7.2 CALCULATING B-FIELDS 63
7.3 WIRING AND HARDWARE CONFIGURATION 66
7.4 BACKGROUND SUBTRACTION 73
7.5 STAGE CALIBRATION 74
8. HTS SQUID HANDLING CAUTIONS 75
Table of Figures
Figure 1-1: SQUID System.................................................................................................. 10
Figure 1-2: Microscope Setup.............................................................................................. 11
Figure 2-1: Cryogenic Dewar .............................................................................................. 16
Figure 3-1 Overview of SMM770 wiring diagram.............................................................. 20
Figure 3-2 SMM770 detailed wiring diagram..................................................................... 21
Figure 3-3: Manufacturer-supplied noise spectrum and tune specs..................................... 22
Figure 3-4 SQUID noise spectrum at (0-200Hz), 81.8 Kelvin, gain=x100......................... 24
Figure 3-5 SQUID noise spectrum at (0-3.2 kHz), 81.8 Kelvin, gain=x100....................... 24

Model SMM 770 Scanning Magnetic Microscope System
TRISTAN TECHNOLOGIES --Page 7
Figure 3-6 SQUID noise spectrum at (0-12.8 kHz), 81.8 Kelvin, gain=x100..................... 25
Figure 3-7: Horizontal Scan of parallel wires 0.003" apart................................................. 26
Figure 3-8: Horizontal scans at increasing liftoffs to parallel wires 0.009” apart............... 26
Figure 3-9: Vertical Scan of parallel wires 0.009" apart ..................................................... 27
Figure 3-10: Vertical scan of parallel wires 0.003" apart.................................................... 27
Figure 3-11: Central peak of a horizontal scan across 76 micron separation meander coil 28
Figure 3-12: US Dollar bill.................................................................................................. 29
Figure 3-13: Image showing what a small amount of processing can accomplish.............. 29
Figure 3-14:: The following output of data is a 3D post processing of the image shown in
Figure 3-11...................................................................................................................... 30
Figure 4-1: Selection of Initialization file............................................................................ 31
Figure 4-2: Main panel after system start............................................................................ 32
Figure 4-3: Track parameters............................................................................................... 33
Figure 4-4: Preview of track to be used for discrete scanning............................................. 34
Figure 4-5: Preview of QuikScan (continuous) track.......................................................... 35
Figure 4-6: Manual control of the sample stage .................................................................. 36
Figure 4-7: iMAG SQUID parameters................................................................................. 37
Figure 4-8: Data acquisition parameters.............................................................................. 38
Figure 4-9: Filter parameters ............................................................................................... 39
Figure 4-10: Scan controls................................................................................................... 40
Figure 4-11: View of scan track........................................................................................... 41
Figure 4-12: Generation of stripchart and 3D graph............................................................ 42
Figure 4-13: Contour lines in the 3D plot............................................................................ 43
Figure 4-14: Cursor usage in the 3D plot............................................................................. 44
Figure 4-15 Illumination control in the 3D plot................................................................... 45
Figure 4-16: Z-axis control.................................................................................................. 46
Figure 4-17: File saving and loading................................................................................... 47
Figure 4-18 Example data file.............................................................................................. 48
Figure 4-19: Deletion of data files....................................................................................... 49
Figure 4-20 Gap between the windown and sample as seen by the video camera.............. 50
Figure 5-1 Measured boil off rate........................................................................................ 52
Figure 6-1 Passive Newport table vs. Newport table with the Activator installed in a
horizontal configuration.................................................................................................. 54

Model SMM 770 Scanning Magnetic Microscope System
TRISTAN TECHNOLOGIES --Page 8
Figure 6-2 Passive Newport table vs. Newport table with activator and without activators
and load of 500lbs........................................................................................................... 54
Figure 6-3 Magnet test ring (option 77B)............................................................................ 56
Figure 6-4 Field profile along Z axis of magnetic ring........................................................ 56
Figure 6-5 Field profile along y and x axis of magnetic ring .............................................. 57
Figure 6-6: Noise spectra of SMM-770 system with 5.5 Gauss external applied field, Gain
x100 58
Figure 6-7: Noise spectra of SMM-770 system with 5.5 Gauss external applied field, Gain
x20 59
Figure 6-8: MS770 mu-metal shield engineering drawings. ............................................... 60
Figure 6-9 Option MS-770 two layer mu metal shield........................................................ 61
Figure 7-1 Elapsed time for SQUID tip coldwon to operating temperatures...................... 62
Figure 7-2 Unsubtracted background................................................................................... 73
Figure 7-3 Subtracted background....................................................................................... 74
Table of Tables
Table 1 System Parameters ..................................................................................................... 23
Table 3-2: SQUID performance tested with iMAG®................................................................. 23
Table 3-3: Iterative Calibration Results for SMM-770............................................................... 25
Table 4 Pt thermometer calibration......................................................................................... 62

Model SMM 770 Scanning Magnetic Microscope System
TRISTAN TECHNOLOGIES --Page 9
DIRECTIVE 97/23/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 29
May 1997 on the approximation of the laws of the Member States concerning pressure equipment
states that “Whereas equipment subject to a pressure of not more than 0,5 bar does not pose a
significant hazard due to pressure; whereas there should not therefore be any obstacle to its free
movement within the Community; whereas this Directive applies to equipment subject to a maximum
allowable pressure exceeding 0,5 bar”. Since the maximum allowable design pressure is less than
0.5 bar, Tristan’s model SM770 is in conformity with DIRECTIVE 97/23/EC.

Model SMM 770 Scanning Magnetic Microscope System
TRISTAN TECHNOLOGIES --Page 10
1. SYSTEM OVERVIEW
The Model SMM-770 Scanning Magnetic Microscope System is a close spaced HTS SQUID
magnetometer system (Figure 1-1) that has been designed and built by Tristan to detect Bz
magnetic field. The main system consists of:
Liquid nitrogen dewar with HTS SQUID Sensor
Scanning stage
X-y tilt stage
Vibration Isolation table
iMAG®SQUID control electronics1, motion control hardware and software, data
acquisition hardware and software and a computer system.
note: some optional items shown
iFL-301-H iMC-303
SQUID Controller
Flux-Locked Loop
Non-Magnetic
Stand-off
X-Y Scanning Table
Liquid
Nitrogen
Dewar
HTS
SQUID
Control Computer
Software
data acquisition,
analysis,
motion control
Sample
Interface Card(s)
X
Y
Z
dc magnet (BZ)
HItachi Camera
Figure 1-1: SQUID System
1iMAG®is a registered trademark of Tristan Technologies, Inc.
Inhaltsverzeichnis
Beliebte Mikroskop Handbücher anderer Marken

Thermo Scientific
Thermo Scientific Nicolet iN10 Leitfaden

National
National DC3-163 Bedienungsanleitung

KERN Optics
KERN Optics OPE-1 Bedienungsanleitung

OPTIKA MICROSCOPES
OPTIKA MICROSCOPES B-150D Bedienungsanleitung

Prior
Prior Lux POL Bedienungsanleitung

Opitec
Opitec Smartscoop 115615 Bedienungsanleitung

VWR
VWR VisiScope 384 Series Bedienungsanleitung

Nikon
Nikon ECLIPSE E200 POL Bedienungsanleitung

Leica
Leica DI C800 Handbuch

ThermoFisher Scientific
ThermoFisher Scientific Continuµm Bedienungsanleitung

ThermoFisher Scientific
ThermoFisher Scientific Continuµm Bedienungsanleitung

Olympus
Olympus SZ61 Bedienungsanleitung