Copyright © 2013, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
ASSA ABLOY
80-9356-0005-020 (01-14)
3
Technical Data
Notes: Input connections - torque to 4.8 in/lbs (.55nm)
Permanent wiring is to be employed as required by local codes.
Activation devices: push plates, access control, mats, touchless wall switches, etc.
Maximum wire size is:
12AWG at terminals HOT and COM (120VAC; 60Hz) on “T1” Power Input Terminal.
14AWG at terminals 1 thru 4 on Accessory Terminal .
120VAC, 60Hz
.6 amps
24 V DC, max. 1.1 Amp.
32-36" (81-91cm)
100-150 lb. (45-68 kg)
Input power:
Power consumption:
Power supply:
Door width*:
Door weight:
Door opening angle:
Push arm: up to - 110°, with reveal 1-1/4" - 5"
(32 - 127 mm)
Hold open time: 0-30 seconds (A.D.A. 5 seconds min.)
5 amps
Circuit breaker:
*Interior Doors Only
Door Prep
Notes:
• All dimensions are given in inches.
• Thickness recommended for reinforcements in hollow metal doors and frames
is charted at the left of this page.
• Do not scale drawing.
• This template information based upon use of 5" maximum width butt hinges.
• Maximum frame reveal is 4" for this application.
• Before beginning the installation, verify that the door frame is properly
reinforced and is well anchored in the wall.
• Unreinforced hollow metal frames and aluminum frames should be prepared
and fitted with 1/4-20 blind rivet nuts, furnished by others.
• Concealed electrical conduit and concealed switch or sensor wires should be
pulled to the frame before proceeding.
Hollow Metal Door Frame Reinforcing
Frame
Material
12 Ga.
.1046
(2.66)
14 Ga.
.0747
(1.90)
16 Ga.
.0598
(1.52)
18 Ga.
.0478
(1.21)
12 Ga.
.1046
(2.66)
10 Ga.
.1343
(3.41)
10 Ga.
.1343
(3.41)
8 Ga.
.1644
(4.18)
18 Ga.
.0478
(1.21)
12 Ga.
.1046
(2.66)
12 Ga.
.1046
(2.66)
10 Ga.
.1343
(3.41)
Reinforcing
Recommended Min. Required
1/8"
(3)
Door
Frame
Templating is based on 1/8" gap between door and frame.
Standard
Optional
Preparation for Fasteners Figure 1
Door or Frame
Fasteners Drill-Sizes
Self-Drilling Screw Wood
(see Note) 3/16” (4.30 mm)
1/4” - 20 machine screw Metal Drill: #7 (0.201” dia.)
Tap: 1/4” - 20
Sleeve nuts and bolts
Hollow
Metal
9/32” (7 mm) through;
3/8” (9.5 mm) door face
opposite to closer
Aluminum
or Wood 3/8” (9.5 mm) through
Aluminum
or Metal No drill required Note: Wood doors/frames.
Pilot hole must be
drilled when using
Self-Drilling Screws.
Always consult door/frame manufacturer
for fastener compatibility with the material