Please use this space for any notes you or your installer may have regarding the installation/
plumbing of this product.
At Bristan, we want to make things as easy as possible for our customers. That’s why we oer solid guarantees on
all our products, eective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product. Alternatively visit
www.bristan.com/register to register your product via a computer.
For full guarantee terms and conditions visit www.bristan.com/guarantees.
General Cleaning
Troubleshooting
Notes
Symptom Cause Remedy
No flow or
low flow
rate
Partially closed isolation valve. Open isolation valve.
Instantaneous water heater cycles on
and o as flow rate or pressure is too
low.
Increase water flow rate or
pressure through system.
Head of water is below the
minimum distance required. 5 meters minimum required.
Hot or cold water being drawn o
elsewhere causing pressure changes
or instantaneous boiler temperature
changes.
Do not use other water outlets when using the taps.
Airlock or partial blockage in the supply
pipework.
Flush through pipework to ensure removal of debris
and any airlocks.
Water
dripping
from taps
This is normal for a short time after using
the taps.
This is caused by residual water tension, the build up
of water in the tap body.
If water continues to drip,
possibly due to the ceramic disc valves
Remove valves and clean, refer to 'Maintenance'
section before starting any maintenance.
Taps do not
turn on
Closed isolation valve. Open isolation valve.
Mains water supply turned o. Turn on mains water supply.
3
3
2
1
1
Maintenance - Valve Cleaning
Remove handle
Your fitting has a high quality finish and should be treated with care to preserve the visible
surfaces.
All surfaces will wear if not cleaned correctly, the only safe way to clean your mixer tap is to wipe
with a soft damp cloth. Stains can be removed using washing up liquid. All bath cleaning powders
and liquids will damage the surface of your fitting, even the non-scratch cleaners.
Note: Never use abrasive detergents or disinfectants or those containing alcohol, hydrochloric acid
or phosphoric acid.
Maintenance- Flow Straightener
2
Unscrew
the flow
straightener
Remove
valve from
the casing
Check that the groove
is clear of any debris
on the inside of valve
casing.
456
Clean the seal
around the
valve and apply
silicon grease
Using a flat screw
driver, remove the
spring and spline.
Pull out valve
body from tap
Rinse and leave to
one side.
Assemble
the valve.
apply
grease and
place back
into the tap
body.
Replace
handle
Prior to doing any
maintenance or
servicing the isolation
valves must be turned
to the
closed/o position.
Important
Rinse
the flow
straightener
Replace
the flow
straightener
into spout