Introduction 3
© Travis Industries 8/2/2018 - 1485 864 GSR2 Op Man
Table of Contents
Introduction ................................................... 2
Important Information ................................... 2
Installation Warnings .................................... 2
Table of Contents .......................................... 3
Features ......................................................... 3
Heating Specifications .................................. 3
Before You Begin .......................................... 6
Remote Control Warnings ........................................ 6
Remote Set-Up ............................................... 7
Verify the Switch is on “REMOTE” ...................... 7
Synchronize the Transmitter to the IFC ............... 7
Location of Controls ..................................... 8
Direct Operation ............................................ 8
Starting the Fireplace for the First Time ..... 9
Intermittent/Continuous Pilot ....................... 9
Switching from Intermittent (IPI) to Continuous
Pilot (CPI) ............................................................ 9
Remote Operation ....................................... 10
Display Overview .............................................. 1 0
Listen for the “Beep” .......................................... 10
Manual On-Off / Smart Thermostat /
Standard Thermostat .................................. 11
Mode Controls (Flame, Blower, Light,
Comfort Control, EmberBed Light) ........... 12
Mode Controls - continued ......................... 13
Accent Light ............................................................ 13
Comfort Control (rear burner) ................................. 13
EmberBed Light (AUX) ........................................... 13
Display Fahrenheit or Celsius .................... 13
Low Battery Indicator ................................. 14
Transmitter Batteries ......................................... 1 4
IFC Batteries ..................................................... 14
Battery Replacement .................................. 14
Battery Installation ............................................. 14
Transmitter Battery Installation .......................... 14
Power Outages ............................................ 14
Child-Proof Feature .................................... 15
Normal Operating Sounds ......................... 15
Normal Operating Odors ............................ 15
Maintaining Your Fireplace's Appearance . 16
Yearly Service Procedure ........................... 16
Grill Installation and Removal ................... 17
Face Installation and Removal .................. 18
Barrier Removal .......................................... 19
Glass Frame Removal and Installation ..... 20
Glass Frame Removal and Installation
(continued) ................................................... 21
Glass Cleaning ............................................ 22
Accent Light Bulb Replacement ................ 22
Ember Light Bulb Replacement ................ 23
Classic Log Set Installation (94500721) .... 24
Wiring Diagram ........................................... 32
Replacement Parts List .............................. 32
CONDITIONS & EXCLUSIONS ................... 33
IF WARRANTY SERVICE IS NEEDED: ...... 33
Features
Works During Power Outages (battery backup)
GreenSmart™ 2 Thermostat / Remote Control
Realistic "Wood Fire" Look
Included Blower for Effective Heat Distribution
Built-In Accent Light (night light)t
EmberBed Light
Standing or Intermittent (GreenSmart) Pilot
Convenient Operating Controls
Variable-Rate Heat Output
Low Maintenance
Heating Specifications
Natural Gas Propane
31K 864 Approximate Heating Capacity (in square feet)* Up to 1,400 Up to 1,400
Maximum BTU Input Per Hour 31,000 31,000
40K 864 Approximate Heating Capacity (in square feet)* Up to 2,000 Up to 2,000
Maximum BTU Input Per Hour 40,000 40,000
* Heating capacity will vary with floor plan, insulation, and outside temperature.