6
7
8
2
4
5
3
1
h
9
12
10
11
'C' PLATE
FIXING KIT
gb
f e
d
a
c
WATERPRESSURE
This mixer is suitable for use at all supply pressures. However for optimum use both
the hot and cold supplies should be reasonably balanced. If the fitting is installed at
low pressure (tank fed), then the minimum distance from the outlet of the nozzle to
the underside of the cold tank should be 2 metres to ensure adequate performance.
This mixer should be installed in compliance with Water Regulations. Where the
supplies are unbalanced, i.e. hot water from the cylinder tank / cold from the mains,
approved check valves must be fitted in the supply pipes.Forfurtherdetails contact
your Local Water Authority.
CONTENTS
1.Rubber O-ring (x1)
2. Rubber ‘C’washer (x1)
3. Metal ‘C’ washer (x1)
4.Nut (x2)
5.Threaded rod (x2)
6. Tail pipe (x2)
7. Pop up rod (x1)
8. Connecting bracket (x1)
9. Waste rod (x1)
10.Flatwasher (x1)
11.Shapedwasher (x1)
12. Waste body (x1)
PleaseNote:In the unlikely event you find a part missing please contact our
immediate despatch of part.
INSTALLATION
1. Identify all components and check for completeness, particularlybeforearranging
fitting.
2. Fit the mixer body to the basin/bidet using the 'C' plate fixing kit. The rubber o-ring
(1) goes between the fitting and the basin/bidet, and the 'C' shaped rubber (2) and
metal washers’ (3) on the underside of the basin/bidet, to be secured by the nut (4)
and threaded rod (5).
3. Fit the tail pipes (6) to the fitting by hand and connect the hot and coldsupplies.
Soft copper tails can be carefully bent and cut to length to meet supply pipes.
4. Fit the pop up waste, with the flat washer (10) below and the shaped washer (11)
above the basin/bidet. It is recommended that a silicon sealant be applied to both
sealing faces of washers 10 and 11. The plug height can be set by, adjusting the
waste rod (9) and operating rod (7) connecting bracket (8), and the screw (g) in the
base of the plug. The waste mechanism can be adjusted using the waste body cap
(h).
5. Fully open both valves, letting them run for a few minutes to check all joints and
connections for leaks.
6. See overthe page for aftercare instructions.
MAINTENANCE
If the fitting begins to drip:
1.Turn off the water supply.
2.Unscrew cap (a), remove indice (b), loosen screw (c) and pull off head (d). Then
unscrew shroud (e) and unscrew ceramic disc valve (f).
3.Carefully clean seating, rubber seal and ceramic disc.
4.Replace valve and head and turn on the water supply.
5.Contact our helpline if problem persists.