TEMPERATURE SETTING MAINTENANCE
To set the temperature, remove the
handle and unscrew the centre screw of
the thermostatic control cover. Rotate the
exposed thermostatic spindle (clockwise
for cold, and anti-clockwise for hot) until the
maximum desired showering temperature
0
is set (42 C-suggested maximum pre-set
temperature).
Then line up the screw head on the back of
the thermostatic control cover with the first
stop on the stop ring itself. Push the control
cover onto the splines and tighten the centre
screw, refit the handle. The thermostat is
now set to its new temperature and can only
be increased or decreased by repeating this
process.
" "
MAINTENANCE
Note: To avoid damage, please remove all chrome
parts before any maintenance takes place.
THERMOSTATIC CARTRIDGES
The 1 concealed thermostatic valve should
give trouble free service, but in the event of
failure, servicing is straight forward.
"
To remove the thermostatic cartridge.
Undo the cartridge clamp nut (take note of
the orientation of the cartridge) and pull the
cartridge out using the temperature control
knob to aid removal. Wash the cartridge with
clean running water and make sure that any
trapped debris has been removed. Dry and
lightly grease the seals (only use silicone
grease) and replace the cartridge making
sure that the locating lug is located in the
recess on the hot side of the valve.
FLOW CONTROL CARTRIDGE
The Flow Control Cartridge uses ceramic discs which normally last indefinitely unless
debris manages to get between them. Wash the cartridge with clean running water, dry and
lightly grease the seal.
FILTERS/CHECK VALVES
The check valves stop cross flow
between the hot and cold supplies.
To clean the Check Valves.
Undo and remove the Check valve.Using
a pair of pliers remove the Non return
valve and filter. Wash the filter with clean
running water, dry and lightly grease the
seals.
CARE OF YOUR SHOWER VALVE
We recommend cleaning the valve with a soft damp cloth.
We strongly advise against the use of ALL cleaning products.
TROUBLE SHOOTING
SYMPTOM SOLUTION
After installation the shower runs HOT
or COLD and will not mix.
Hot and cold supplies are plumbed the
wrong way round.
Remove the thermostatic cartridge,
undo the clamp nut and pull the cartridge
out (using the temperature control knob
to aid removal).
Reinstall it with the locating lug pointing
away from the inlets.
Shower will not run hot enough when
first installed.
Maximum temperature needs adjusting,
see temperature setting .
Cold water tracking through the valve
into the hot water system.
Check and clean the check valve
cartridges and filters located under
the check valves.
Very low flow or no flow (gravity). Check hot and cold feeds (the valve will
shut down if either the hot or cold supply
fails).
FILTER
NON RETURN
VALVE
CHECK
VALVE
LOCATING LUG